Abstract

New geological and structural facts have been identified under the auriferous lateritic cover in Garga Sarali, Ndokayo area. Data were collected using AMT receiver system with frequencies ranging from 20 Hz to 50000 Hz. It consists of 16 AMT stations along 03 profiles, over Pan-African formations of East Cameroon. The wide frequency range enabled us to probe deep into the subsurface to obtain necessary information. Using Imagem software, coherency of data has been evaluated and only the data with a coherency below or equal to 0.7 have been considered. Two programs were used to map the subsurface. The pseudosections were obtained using IPI2WIN-MT, while geoelectrical sections were obtained using Stratagem Resistivity Plotter. Analysis of the curves of dimensionality tests shows that there is not always a complete superposition between the two telluric directions, translating the fact that the variation of the resistivity is not 1D, but rather 2D or 3D. Major features of 2D resistivity model from the respective profiles were identified. These features include a set of lower resistive formations going from the surface to 1000 m depth, lying on a set of resistive formations that appears at the surface and below the lower resistive formations. However, a very conductive layer was observed in depth in the three profiles. These facts show that the study area is made up of mixture of both conductive and resistive materials, suggesting a prolongation of the overlap between the Congo Craton and the Pan-African in depth to the north and the location of the CC/Pan-African limit above 4°N parallel accordingly. Deeper electrical discontinuities, interpreted as faults following a NE-SW trend, were highlighted. All these new data suggest that the study area underwent an intense tectonic activity with ductile to brittle deformations due to the presence of the BOSZ.

1. Introduction

The Pan-African tectonic evolution in Cameroon is marked by large scale shear zones that have intensely transported early structures [1, 2]. Cameroon neoproterozoic units belong to the North Equatorial Fold Belt (NEFB) which is affected by the Central African Shear Zone (CASZ) and defined as a pre-Mesozoic crustal strike-slip fault system [1, 2]. The CASZ forms two branches in Cameroon: the Central Cameroon Shear Zone (CCSZ) to the north and the Sanaga Fault (SF) to the south. The SF system is well represented in the east part of Cameroon by the Bétaré-Oya Shear Zone (BOSZ), where many mineralized substances are well established. The CCSZ is defined as a Pan-African postcollisional ductile fault, as a transcontinental structure marked by folds, parallel, or en-echelon relays [3], and as major lineament of the Pan-African orogen of Central Africa [4].

In geophysical prospecting, AMT method is used and considered as a key tool in mineral exploration [5], in geothermal investigation [68], in potential radioactive waste disposal characterization [9], and in the identification of tectonics structures [10].

Magnetotelluric investigations have been carried out in the east region of Cameroon. A recent study [11] permitted through the use of the MT (AMT) high frequencies and 2D modelling of resistivity and phase pseudosections, to establish the tectonic setting and by the same way a system of folds and faults in southwestern part of the present study area. The interpretation of the AMT data and correlations with geological facts confirmed the author’s proposition that the southwestern part of the study area is perfectly linked to the collision between the Pan-African Chain and the Congo Craton. Fractures have been highlighted from the image of the subsurface by combining the classical and the Bostick approaches in the interpretation of AMT data in the Akonolinga-Ayos region, westward from the current study area [12].

Other studies [1315] by aeromagnetic and gravimetric methods were carried out in the southeastern part of the present study area and the results obtained were used to update the previous geological map and to highlight the presence of a deeper major tectonic feature, oriented E-W along the 4° northern parallel emphasizing the presence of a E-W normal faults system in the Mengueme-Akonolinga region [13].

In spite of these studies, the fact that little or nothing is known about the internal structure of a large part of the eastern region of Cameroon still remains. Also, most of these studies are regional, therefore raising the debate about the internal structure and the continuity of the observed superficial structural lineaments at depth.

The aim of the present investigation was to study the electrical structure of the crust beneath the Garga Sarali neoproterozoic formations, which belong to the eastern gold district of Cameroon. This could help us understand better the relationship between the NE-SW, E-W, and N-S trending shear zone and the presence of mineralization at surface in that region of Cameroon. For that purpose, we have combined geophysical (AMT) investigations with some geological field data to enhance our results.

2. Geology Setting

2.1. Regional Geology

The study area belongs to the Pan-African belt (Figure 1), also interpreted as the result of the convergence and collision between the steady Archaean Congo Craton to the south and one or two Paleoproterozoic plates [16, 17]. Three major geological domains from south to north of the Pan-African belt in Cameroon are well identified [1820].(i)The southern domain, which comprises Pan-African meta-sedimentary units, contains formations that were thrust onto the Archaean Congo Craton towards the south, during an event marked by four stages of ductile deformations corresponding to E-W to NW-SE contraction (D1 and D3) and N-S to NE-SW extension (D2).(ii)The central domain corresponds to a large NE-striking transcurrent fault zone, including the Adamaoua and Tibati Banyo faults to the north and the SF to the south.(iii)The northern domain consists of subordinate 830 Ma old metavolcanic rocks of tholeitic and alkaline affinities, which are associated with metasediments known as the Poli series and widespread 630–660 Ma old calc-alkaline plutonic rocks known as orthogneisses, which result from a major crustal accretion episode.

2.2. Local Geology

The study area (Figure 2) is located 30 km away from Bétaré-Oya, between latitudes 5°19′N and 5°31′N and longitudes 13°59′E and 14°10′E. It belongs to the eastern part of the central domain and is characterized by a dentritic hydrographic network emphasizing a variety of tectonic features (Figure 3). Previous geological investigations recognized two contrasting terranes [21, 22]. The northwestern terrane consists mostly of NE-SW elongated low-grade schist with Au deposits, including a volcanoclastic schist (so-called Lom Schist), that is associated with subordinate conglomeratic quartzites and intruded by voluminous plutonites. The eastern terrane, by contrast, is characterized by a lack of low-grade metasediments with Au deposits and by high-grade metamorphic gneiss and migmatites intruded by granite suites [21, 22]. The boundary between these two terranes is marked by a several-meters-wide NE-trending mylonitic zone referred to hereafter as Bétaré-Oya Shear Zone (BOSZ).

Recent studies show that the area belongs to the central domain. The lithology is made up of lateritic duricrust terranes, migmatites and gneisses (ortho), schist referred to as the Lom Schist belt (Figure 3(c)), metaleucogranites, metagranodiorites, porphyritic granites (Figure 3(b)), fine grained granites, and some pegmatite veins [1].

The study area is affected by the strike-slip fault (Figure 1) known locally as the BOSZ and a relay of the SF which divided the study area into two parts: a northwestern and a southeastern region [1]. The southeastern zone is dominated by various gneissic granitoids and minor bodies of porphyritic granites, while the northwestern zone is dominated by late granitoids intrusions and early gneissic rocks with subordinate schist [1].

A preliminary assessment through a superposition of the structural map and the satellite images analysis of the area (Figure 4) displays an alignment of tectonic lines, lineaments, and foliations with the choice of the profiles, which are cross-cutting the observed structural features.

3. Method, Data Acquisition, and Processing

3.1. Method

The magnetotelluric (MT) method finds its basic principles within the electromagnetic field theory [23], in which it is demonstrated that the MT wave is a plane wave [24]. The MT method is applied in structural geology and geothermal and mineral prospecting [12, 2528]. In MT method, natural electromagnetic fields are used to investigate the electrical structure of the earth, based on its resistivity. The MT method is unique because of its capability to explore from very shallow to very great depth without using any artificial power source and with no environmental impact. MT data acquisition involves the simultaneous measurement of natural electric and magnetic fields at any point on the earth’s surface, in order to deduce the resistivity of rocks directly under the receiver. In reality, the subsurface is inhomogeneous, and the apparent resistivity is determined instead of the true resistivity [10, 29, 30], according to the following relation: , where is the period of the wave in seconds, is the electrical field in the direction, and the magnetic field in the direction perpendicular to .

The MT investigation at high frequencies is known as the audio frequency MT or simply audiomagnetotellurics (AMT). AMT enables investigations from shallower depths (1 m) to more than 1 kilometre (depths of 7 to 10 km are reachable in some cases). Natural electromagnetic sources related to the MT/AMT method originate from spherics and thunderstorms that hit the earth and consequently induce a ground electromagnetic field. However, when dealing with AMT soundings, natural signals are generally weak in the 2000–5000 Hz frequency range, also known as the AMT dead-band [24, 31]. This weakness in natural signals strength is improved by using artificial signals which strengthen the background fields. The technique is a variant of the AMT called controlled source AMT (CSAMT).

AMT interpretation software is used to estimate the ground electrical impedance from a series of simultaneous measurements of local electric and magnetic field fluctuations made over a period of several minutes. The ground impedance is a complex function of frequency where higher-frequency data are influenced by shallow or nearby features while lower-frequency data are influenced by deep structures [32]. An AMT sounding provides an estimate of vertical resistivity distribution and indicates the geoelectrical complexity beneath a sounding site.

The resistivity of geologic unit depends largely on its fluid content, porosity, degree of fracturing, temperature, and conductive mineral content [33]. Saline fluids within the pore spaces and fracture openings can reduce resistivity in a rock matrix. Also, resistivity can be lowered by the presence of conductive clay minerals, carbon, and metallic mineralization. Increased temperature causes higher ionic mobility and mineral activation energy thereby reducing rock resistivity significantly. Unaltered and unfractured igneous rocks are normally very resistive, with values typically 1,000 ohm-m or greater [34]. Also, fault zones can appear as low resistivity units of less than 100 ohm-m when they are comprised of rocks fractured enough to have hosted fluid transport and consequently mineralogical alteration [34].

3.2. Data Acquisition

To conduct the study, geophysical data were collected with a Stratagem EH-4 system from [32]. Stratagem EH-4 is a system which utilizes both natural and man-made electromagnetic signals to obtain continuous electrical sounding over the earth surface. The Stratagem system consists of two basic components (Figure 5): (1) a receiver unit that allows the use of four/five electrodes and two magnetic sensors and (2) a transmitter which provided artificial signals required to augment the natural field and improve the data quality [24, 32].

AMT data were acquired using the Geometrics STRATAGEM EH4 unit along three profiles following Garga Sarali, Ndokayo road (Figure 1), with a total of 16 soundings. These data were processed to provide tensor impedance measurements for interpreting complex 2D structures. To acquire soundings, the STRATAGEM EH4 was assembled at each station with a 25-meter dipole length in the X (TE mode) and Y (TM mode) directions using 4 buffered electrodes with stainless steel stakes. The choice of the orientation of profiles and the soundings points has been made on the basis of geological data of the area. In fact, the main structural trend of the area followed the N042. Data acquisition was performed far away from electrical networks and human activities to avoid noises. Ndokayo profile is 4090 m in length, while Oudou is 3200 m in length and Garga Sarali is 7700 m in length. According to the geological map [21] and field observations, the three profiles are crossing two mica porphyritic granites, porphyritic granite, embrechites gneisses, and schists. Distances between profiles and the base profile Ndokayo are reported in Table 1.

3.3. Data Processing

After transforming the recorded time-series data to frequency domain, standard processing method was employed to determine the apparent resistivity and phase tensor at each sounding site [32]. The apparent resistivity and phase are related through the Hilbert transform. The phase is proportional to the slope of the apparent resistivity curve on a log-log plot, except from the baseline of 45 degrees [27]. Predicted values of the electric field can be computed from the measured values of the magnetic field [27]. The coherence of the predicted electric field with the measured electric field is a measure of the signal-to-noise ratio provided in the -predicted coherency plots. The coherency obtained during the data collection has a signature that is acceptable with a value that is aligned almost to a good precision (Figure 6).

The electric and magnetic fields were measured in two directions (orthogonal and horizontal). The tensor impedance, parameterised as apparent resistivity and phase, was obtained from the time-series signals. Signals were converted to complex cross-spectra using a Fourier-transform technique. A least-squares, cross-spectral analysis was then used to solve for a transfer function (impedance) that relates the observed electric fields to the magnetic fields under the assumption that the earth consists, respectively, of two inputs (magnetic fields) and two outputs (electric fields) linear system [32].

For two-dimensional (2D) earth model, the diagonal terms of the impedance tensor are zero. The off-diagonal terms were decoupled into transverse electric (TE) and transverse magnetic (TM) modes. When the geology satisfies the 2D assumption, the TE mode measures electric field parallel to geologic strike and the TM mode measures electric field perpendicular to geologic strike. Data were processed with a fixed rotation parallel and perpendicular to regional strike. The Stratagem Resistivity Plotter (program made to visualize and edit 2D modelling results produced by the Imagem software [32]) was used for making 2D plots of Stratagem Resistivity data. This program uses the Python Matplotlib scientific plotting. The program allows the combination of high and low frequency mode soundings into one plot.

Analysis of the curves of dimensionality tests (Figure 6) shows that there is not always a complete superposition between the two telluric directions. This confirms the fact that the variation of the resistivity is not 1D, but rather 2D or 3D. Nevertheless, the superposition observed can refer to a model of structure, 1D or 2D, but in comparison with complex tectonics of the study area, 2D interpretation is more indicated.

Values of the electric field can be estimated from measurements of the magnetic field [27]. Coherence between the values of the electric field predicted and those measured is the ratio between the signal and the noise ([signal]/[noise]). This ratio defines the quality of the recorded data. The values of coherence lie between 0 and 1 (where 0.5 corresponds to a level of signal equal to the noise). Figure 7 shows the coherency test on station 2 of the Ndokayo profile and that of station 2 of the Oudou profile. For this study, only the data with a coherency below or equal to 0.7 have been considered (Figure 7).

4. Results

4.1. Resistivity Profiling Curves
4.1.1. Ndokayo Profile

The Ndokayo resistivity profile (Figures 8(a) and 8(b)) presents a zigzag form testifying the variation of the resistivity with depth, with peaks that characterize the changes in the nature of the bodies or formations crossed by the current. Observation of the Ndokayo profile makes it possible to locate two (02) zones of anomalies. Indeed, the variation of the resistivity between the Nd1 and Nd3 stations in the high frequency domain shows the passage of the current in the fairly resistive zones. This evolution is abruptly interrupted in the field of low frequencies marked by a sharp drop of the resistivity. This reflects the existence in depth of a sufficiently conductive body. This phenomenon is still observed between the Nd4 and Nd5 stations, where a discontinuity is identified at the Nd4 station (line in red).

4.1.2. Garga Sarali Profile

At both low and high frequencies domain, the resistivity profiles from the Garga Sarali (Figures 7(c) and 7(d)) display low resistivity values at great depth. Particularly, there is a very conductive channel between stations GS2 and GS6. The above-stated channel seems to be bordered by two major electrical discontinuities at GS2 and GS6 (Figures 8(c) and 8(d)). These discontinuities can be interpreted as faults. The irregular variation of the resistivity confirms the heterogeneity of the basement of the area and suggests its folded character and its geological setting marked by brittle-ductile deformations.

4.1.3. Oudou Profile

The curves obtained from the Oudou profile (Figures 9(a) and 9(b)) disclose a main electrical discontinuity at high and low frequencies domain, centred at station Oud2 and characterized by a decrease of the resistivity. Geologically, this rough variation of the resistivity highlights the transition of a facies of high resistivity to facies of low resistivity. This passage would thus correspond to an electric discontinuity. The resistivity variation also suggests the heterogeneity of the environment.

4.2. Pseudosections
4.2.1. Ndokayo Profile

The observation of the apparent resistivity and phase pseudosection of the Ndokayo profile helps to identify (Figure 10) a conductive area that extends from station Nd1 to station Nd4 and beyond at high frequencies, which was more emphasized between stations Nd2 and Nd4. Also, a highly conductive zone was observed at depth (low frequency domain), particularly below the stations Nd3, Nd4, and Nd5. A precise observation shows that this area is separated from the first conductive zone (high frequency domain) by a resistive zone whose signatures are visible at the surface at the station Nd5. This resistive zone extends in depth with an emphasis under stations Nd1 and Nd3, where it seems to represent the basement materials. However, there is a conductive channel that divides this resistive zone in two entities. The observed facts suggest the presence of a discontinuity in depth.

4.2.2. Garga Sarali Profile

The observation of apparent resistivity and phase pseudosections (Figure 11) of the Garga Sarali profile shows a conductive zone between GS1 and GS2 and surrounding GS5 and GS6 which is observed as high frequency domain along the profile. The second that has underlain the first one is more resistive, and it is undulated with depressions at stations GS2 and GS6, suggesting the presence of electric discontinuities.

A third zone appearing beneath the second is conductive as the first zone. However, some resistive layers below the station GS7 are identified at low frequencies. These features (Figure 11) show that the area testified an intense tectonic event that is underlined by a deeper electric discontinuity under station GS5.

4.2.3. Oudou Profile

The apparent resistivity and phase pseudosections of the Oudou profile (Figure 12) underline a depressions process which affects the resistive formation cropping out at station Oud4 and extends to a great depth (low frequency domain).

This depression is marked by conductive material fillings that extend from station Oud1 across the section, over 3000 meters. This conductive region extends in depth (medium frequency) below the station Oud2, where it seems to separate into two high resistivity blocks and appear again at great depth (low frequency domain) below stations Oud3 and Oud4. This disposition suggests the presence of a discontinuity at the station Oud2 and a folding process that has affected the area.

4.3. Geoelectrical Section (2D Modelling Pseudosection)
4.3.1. Ndokayo Profile

Figure 13 represents the geoelectrical section of Ndokayo profile. It generally shows the inhomogeneous character of the area.

The major features observed on the 2D geoelectrical section from the Ndokayo profile are given as follows (from surface to depth):(i)The first geoelectrical layer (Rho ≤ 1000 Ω·m) spans from Nd1 to beyond Nd4, where it is interrupted by the outcrop of the underlying layer (thus suggesting a horizontal discontinuity). This first layer reaches 400 m depth below Nd1 and 300 m below Nd4. However, it slightly thins between Nd2 and Nd4. The observed conductive zone may correspond to sediment and metasediment deposit from the Lom series.(ii)The second geoelectrical layer (1000 Ω·m < Rho ≤ 4000 Ω·m) appears in depth between 400 m and 600 m at Nd1, between 300 m and about 1100 m at Nd4, and from surface to 600 m depth at Nd5. It is characterized by a paroxysmal bulge at Nd3. This layer outcrops beyond Nd4 (from the profile’s origin) where it suggests a horizontal discontinuity therein, which could be interpreted as a change in the nature of encountered formation. Also, the trace on the section depicts an oval shaped target below station Nd4. The layer’s attitude around station Nd4 infers a collapse of the underlying terrains. The second geoelectrical layer can be interpreted as two mica porphyritic granites, according to the resistivity range values.(iii)The third geoelectrical layer (4000 Ω·m < Rho < 7000 Ω·m and above 7000 Ω·m) appears between 600 m and up to 1000 m depth at Nd1 where it is embedded within the second layer. It has an average thickness of 200 m along the whole profile. These uplifts are separated by a depression that is bounded by steep slopes, inside of which two strongly resistive blocks are identified, respectively (Rho ≥ 7000 Ω·m). It presents alternating upraised (from Nd2 to Nd3 and at Nd5) and downthrown (centred at Nd4) blocks. The upraised block from Nd2 to Nd3 is responsible for the thinning of the overlying formations therein. Besides, the downthrown block is probably a collapse of the basement between Nd3 and Nd5. The third geoelectrical layer can be interpreted as formations that constitute the basement (probably granitoids).

A main electrical discontinuity is identified on the geoelectrical section of Ndokayo profile. This highlighted discontinuity can be interpreted as vertical faults with a NE-SW strike based on their shape and orientation. The fault may have probably resulted from the fracturing and the compartment of the basement along with vertical displacement of blocks (Figure 13).

4.3.2. Oudou Profile

The observation and analysis of the geoelectrical section of the Oudou profile (Figure 14) enable outlining features or layers having the same geoelectrical characteristics as those from the first profile (Figure 14). The features as observed from shallow depth (Figure 14) are given as follows:(i)The first geoelectric layer corresponds to conductive terrains (Rho ≤ 1000 Ω·m). It has an average thickness of 100 m with a perceptible thinning beyond station Oud3.(ii)The second layer (1000 Ω·m < Rho ≤ 4000 Ω·m) appears between 100 m and 400 m beneath Oud1, thickens up to 600 m at Oud2, and then becomes thinner up to the end of the profile.(iii)The third layer (4000 Ω·m < Rho < 7000 Ω·m) corresponds to more resistive terrains. This layer has an average thickness of 300 m. It is marked by a steep slope from Oud1 to Oud2 and gentle slope from Oud3 to Oud4. These two slopes configure the third layer like a boat which dips to the SE (beginning of the profile). The boat-like shape of the third layer matches that of the underlying fourth layer (Rho ≥ 7000 Ω·m) which is interpreted as the basement in the Oudou area.

4.3.3. Garga Sarali Profile

In the same way as in the previous profiles, the 2D geoelectrical section from the profile (Figure 15) in the Garga Sarali area exhibits a four-layer earth model. Downward from surface, the feature appears as follows:(i)The first layer (Rho ≤ 1000 Ω·m) surmounted by a very low resistive layer has an average thickness of 200 m. It is characterized by undulations induced by the roughness of the underlying layer’s topography.(ii)The second layer (1000 Ω·m < Rho ≤ 4000 Ω·m), as stated above, has a very irregular topography affecting the thickness. However, between stations GS3 and GS6, that thickness increases up to a mean value of 600 m. A nucleus of conductive materials is observed, especially at GS4. The isoresistivity contours are subvertical at GS3 and GS6, suggesting the presence of discontinuities at these points, respectively.(iii)The third horizon is characterized by resistivity values between 4000 Ω·m and 7000 Ω·m. with a strong bending from GS1 to GS3 and subvertical contours at GS3 and GS6. These subvertical contours confirm the presence therein of the discontinuities highlighted in the layer above (the second layer). These discontinuities delineate a graben between GS3 and GS6, probably induced by the collapse of the basement in the Garga Sarali area.

The geoelectrical section obtained along Garga Sarali profile shows folded structures and two vertical electrical discontinuities at GS4 and GS6 interpreted as faults oriented NE-SW. These faults seem to be associated with the tectonic events.

The results obtained from all the profiles above point to the fact that the study area has undergone deformation by folding and faulting processes. The identified electrical discontinuities followed NE-SW direction and are correlated with the CCSZ. Furthermore, the study area is made up of a mixture of both resistive and conductive formations. Recent studies [10, 12] suggest that the resistive formations account for the Congo Craton (CC) and the conductive ones belong to the Pan-African system; this mixture of materials suggests a prolongation of the overlap between the CC and the Pan-African to the north at great depth. Hence, the study suggests that the CC/Pan-African limit is located beyond latitude 4°N. We can therefore assume that the study area underwent a multiphase tectonic activity.

5. Discussion

Field observations, existing geological data, and satellite imagery analysis of the study area, combined with AMT investigation, show that the subsurface resistivity distribution along the three profiles is in similar geological and structural environments. Ndokayo profile is crossing mica porphyritic granites, while Oudou profile runs over porphyritic and embrechite gneisses and Garga Sarali profile was on the Lom schists and porphyritic granites.

The analysis of satellite imagery and the relevant surface structural lineaments confirms the presence of three structural families with a main NE-SW orientation followed by NNE-SSW to N-S and E-W (Figure 3). Some electrical discontinuities interpreted as faults and oriented NE-SW as the BOSZ were highlighted. A major fault was identified down the station Nd4 of the Ndokayo profile, while two (02) other faults were identified along the Garga Sarali profile (GS4 and GS6). The irregular shape of isoresistivity contours (folds, vertical to subvertical) and the geological facts (crushed and oriented rocks) allow us to believe that an intense tectonic activity has taken place in the study area. They have the same orientation as the surface structural lineaments and some are correlating (Figure 16). These faults resulted from the deformation phases (D2 and D3) that have affected the study area. The results from previous geological studies [1, 35, 36] strengthen the present results.

The analysis of the apparent resistivity profiles, pseudosections (apparent resistivity and phase), and geoelectrical sections from the three AMT profiles shows that the structures are well deformed by folded and fractured events that correspond to the Pan-African orogeny materialised by the SF and the BOSZ [3]

The investigated area is closer to the transition zone between the Pan-African and the Congo Craton domains. This is confirmed through the mixtures of conductive and resistive materials observed beneath the investigated area, suggesting a prolongation of the overlap between the Congo Craton and the Pan-African in depth, to the north. Other studies confirm this overlapping [10, 12] and establish the CC/Pan-African limit above the northern 4° parallel. However, studies were carried out (between latitudes 3°30N and 4°30N) some distance away from the current study area (which stretches from latitudes 5°N to 5°30N); hence, we established that the CC/Pan-African limit in the area is located north beyond the known limit documented by [10, 12]. Investigations shall be carried out in the future to explain the shift between those two locations.

Geophysical investigation shows that the NW parts of the AMT profiles, which are located closer to the BOSZ, present resistive formations that are sometimes shallow close to the surface. In the SE part, these formations are also identified. This configuration would highlight a characteristic of the BOSZ, which would be not only a shear zone but also a system of faults zone with raised and collapsed compartments.

The results obtained from the current study are of great importance in mining exploration. The geological investigation of the study area reported the presence of porphyritic plutonic rocks (granites) that were affected by contact metamorphism. The three AMT profiles (Ndokayo and Garga Sarali) display deeper discrete zones that are very conductive (Figure 13). These conductive areas may correspond to the presence of fluids, clay minerals, or metallic (Cu, Au, and Ag) mineralized bodies.

The combination of geological facts and audiomagnetotellurics sounding analyses and modelling has led to the detection of electrical discontinuities. These electrical discontinuities oriented NE-SW are linked to the Central Cameroon Shear Zone [3]. The prolongation of these tectonic features has been revealed by recent geophysical studies carried out in adjacent areas [11, 12, 37, 38] in the southern and the northern borders of the area under study. Hence, there is a link between the present study and the previous ones, as it shows that the fault oriented NE-SW was derived from the tectonic event that has occurred during the Pan-African orogeny and it is directly aligned with the Central African Shear Zone (CASZ).

6. Conclusion

The integration of geophysical and geological data led to the following conclusions:(i)The analysis, modelling, and interpretation of audiomagnetotellurics data show the existence of electrical discontinuities that could be interpreted as faults and which correlate with the surface structural lineaments trend evidenced by satellite imagery analysis.(ii)The identified faults oriented NE-SW were linked to the Central Cameroon Shear Zone and linked to those discovered by recent studies using aeromagnetic and gravity interpretation, based on the multiscale horizontal derivative of the vertical derivative (MSHDVD) methods applied in adjacent areas situated in the northern and southern borders of the present study area.(iii)The study area is made up of mixture of conductive (Pan-African) and resistive (Congo Craton) materials that suggest a prolongation of the overlap between the Congo Craton to the north and the location of the CC/Pan-African limit above N04°.(iv)The fault system oriented NE-SW was formed by the tectonic event that occurred during the Pan-African orogeny and it is directly aligned with the Central African Shear Zone (CASZ).(v)The structural dips on the geological map correspond to the orientation of electrical discontinuities.(vi)The three AMT profiles (Ndokayo, Oudou, and Garga Sarali) show conductive anomalous zones that are distinct, running from the surface to great depth. These anomalies may correspond to the presence of fluid, conductive clay minerals, or metallic mineralized bodies.(vii)The BOSZ is not only a shear zone but also a system of faults with raised and collapsed compartments.

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this paper.

Acknowledgments

The authors are grateful to Mr. Ava Christophe, General Manager of Harvest Mining Corporation (HMC), for the logistics he provided to enable field works.