99mTc-Sestamibi/123I Subtraction SPECT/CT in Parathyroid Scintigraphy: Is Additional Pinhole Imaging Useful?
Table 3
False-negative and false-positive findings with –sestamibi/123I subtraction SPECT/CT alone and with an additional pinhole image. Case number with a letter (a and b) refers to the same patient.
Case number
Location
Clinical background
SPECT/CT
SPECT/CT with pinhole
Comment
1
LL
pHPT
FN
TP
Residual activity was faintly visible in SPECT/CT, but was classified as negative. With additional pinhole image correct classification was done.
2
UL
pHPT
FN
TP
3a
LL
sHPT
FN
TP
4a
LL
pHPT
FN
TP
3b
LR
sHPT
FN
FN
No clear residual activity
5a
UR
pHPT
FN
FN
6
UR
pHPT
FN
FN
7
LL
pHPT
FP
TN
Very uneven iodine uptake
4b
UR
pHPT
FP
TN
Subtraction artefact (edge effect)
8
LL
pHPT
FP
TN
Subtraction artefact (edge effect)
9
LR
pHPT
FP
TN
An iodine-negative nodule
5b
LL
pHPT
FP
FP
A large thyroid cyst at left side
10a
LR
pHPT
FP
FP
Subtraction artefact
10b
LL
pHPT
FP
FP
Subtraction artefact
UL = upper left; LL = lower left; LR = lower right; UR = upper right.