Abstract

We report a skew-Laplace statistical analysis of both flow cytometry scatters and cell size from microbial strains primarily grown in batch cultures, others in chemostat cultures and bacterial aquatic populations. Cytometry scatters best fit the skew-Laplace distribution while cell size as assessed by an electronic particle analyzer exhibited a moderate fitting. Unlike the cultures, the aquatic bacterial communities clearly do not fit to a skew-Laplace distribution. Due to its versatile nature, the skew-Laplace distribution approach offers an easy, efficient, and powerful tool for distribution of frequency analysis in tandem with the flow cytometric cell sorting.

1. Introduction

Bacterial growth has been intensively studied during the last century, and the understanding of bacterial cultures has increased from decade to decade. However, the intrinsic variability and heterogeneity of bacterial axenic cultures (Vives-Rego et al. [1], Julià and Vives-Rego [2]), as well as the complexity of the different processes that take place in each phase of the growth (Prats et al. [3, 4]), still constitute a substantial difficulty when attempting to accurately study, model, and predict the bacterial growth and the resulting populations and in particular the cell size distribution.

Flow cytometry combines direct and rapid assays to determine the number, cell-size distribution and other biochemical information regarding individual cells (Robinson [5], Shapiro [6], Vives-Rego et al. [7]). This makes it particularly attractive for studying heterogeneous bacterial populations (Davey and Kell, [8], Vives-Rego et al. [7]). Flow cytometry cell-size estimates are based on the intensity of forward light scatter (FS), which is preferred to 90 scatter or side light scatter (SS) do to its high signal intensity and its insensitivity to sub-cellular structure—conventionally described as “granulosity.” FS is generally assumed to be proportional to bacterial size (Christensen et al. [9], Julià et al. [10], Koch et al. [11], López-Amorós et al. [12]), although this relationship between particle size and FS is not monotonic as it is also affected by cell structure and chemical composition (Shapiro [6]).

Studies on the heterogeneity of bacterial axenic cultures are scarce despite there is an obvious need to understand its morphological, biochemical, and genetic bases. The starting point in the statistical analysis of microbial heterogeneity is selecting an appropriate mathematical expression for the so-called “cumulative distribution function” for a measured parameter. More precisely, a cumulative probability distribution function is a function which gives, for each real value 𝑥, the probability that the measured variable takes values smaller or equal to 𝑥. The normal distribution (also called the Gaussian or the bell curve) remains the most commonly encountered distribution in nature and statistics due to the central limit theorem: every variable that can be modeled as a sum of many small independent variables should be normal. However, it has been clearly shown that bacterial cell size or mass distribution does not follow the Gaussian pattern (Koch [13], Vives-Rego et al. [14], Wagensberg et al. [15]).

There is a diversity of mathematical equations used to approximate probability distributions for experimental data. They reflect to some extent the high diversity of mechanisms that exist underlying the variability observed in natural processes and biological materials. The selection of a specific mathematical model depends on the available measurement tools and the theoretical paradigm used to interpret the studied process. In any case, the type of distribution might provide important clues as to the mechanism of variability. Cell size variation is also a sensitive parameter that is influenced by the physiological and molecular-genetic state of a microbial population, for example, it can change due to the number of plasmid copies in recombinant strains (Lyncha et al. [16]) or after a temperature shock (Scherbaum [17]), osmotic stress (Elmoazzen et al. [18]) or after exposure to various pollutants (Biggs et al. [19], Ting et al. [20], Törnqvist and Claesson [21]). Therefore, the analysis of size distribution has numerous applications in biotechnological, biomedical, and environmental research.

Statistical analysis of flow cytometry data for Gram negative bacteria revealed that the skew-Laplace distribution is an effective option among other known probability functions (Julià and Vives-Rego [2]). In the present paper, we further expand this study to encompass a wider range of microorganisms including Gram-negative and Gram-positive bacteria, eukaryotic unicellular organisms (yeasts), aerobic and anaerobic species in axenic cultures or chemostat cultures as well as aquatic microbial communities containing variable mixtures of bacterial species.

We show in this paper that the skew-Laplace distribution constitutes an effective model for many axenic microbial cultures tested for scatter cytometric properties and to a lesser extend for cell size. Finally, we discuss how statistical analysis of frequency plots can be used as a tool in microbial biotechnology, cell cloning, and population dynamics studies.

2. Methods

2.1. Microbial Strains, Culture Conditions, Continuous Cultures, and Aquatic Samples

Experiments were performed with the strains listed in Table 1. Yeasts were grown in Sabouraud Maltose Broth at 26C. Bacteria were grown in Brain and Hart Infusion medium (BHI) by incubation at 30C. Batch cultures were inoculated with 10% of an overnight culture and shaken at 150 r.p.m. for 6, 20, or 36 hours. The chemostat cultures consisted of 250 mL flasks containing 50 mL of BHI culture permanently mixed by magnetic stirring and incubated at 30C. The growth was started with a 2% inoculum of an overnight batch culture. The fresh medium input fluxes as well as the overflow output were controlled by a peristaltic pump (Minipuls S3, Gilson). Growth was monitored by recording the optical density at 600 nm. Once the steady-state was reached, samples were taken for the flow cytometric and electric sizing assessment. The Laplace fitting was also applied to the microscopic bacterioplankton size data from Lake Tanganyika (Africa) kindly provided by S. Pirlot and P. Servais (Pirlot et al. [22]) as well as from the coastal Cantabric Sea (Spain) (Latatu [23]).

2.2. Flow Cytometric Analysis

Flow cytometric experiments were carried out using an Epics XL flow cytometer (Coulter Corporation, Miami, Florida). Excitation of the sample was done using a standard 488 nm air-cooled argon-ion laser at 15 mW power. The instrument was set up with the standard configuration. The forward scatter (FS) sensor is a photodiode that collects the forward scatter, which is the laser light scattered at narrow angles (typically 2-11) to the axis of the laser beam. When light reaches it, the FS sensor generates voltage pulse signals proportional to the amount of light the sensor receives. Sensitivity of the flow cytometer is sufficient to detect 0.5 𝜇m particles. The side scatter (SS) is a photo diode sensor that collects the amount of laser light (488 nm) scattered at an approximate 90 angle to the axis of the laser beam. The amount of SS is proportional to the granularity of the cell that scattered the laser light. In our experiments, optical alignment was based on an optimized signal from 10 nm fluorescent beads (Flowcheck, Coulter Corporation, Miami, Florida, USA). Forward light scatter signal intensity is strongly affected by the wavelength of light used and by the precise range of angles over which light is collected, the latter being determined by focal lengths and the numerical apertures of the collecting lenses, including the size, shape, and position of irises, slits, and obscuration bars in the optical system. Since no two manufacturers of flow cytometers use the same optical design for forward scatter measurements, it is unlikely that exactly the same results will be obtained from measuring the same cells with different instruments. Theory predicts, and experiments confirm (Julià et al. [10]), that, even for uniform particles, forward scatter amplitude will not be a monotonic function of particle size. Data were analysed with WinMDI version 2.5 Software (Windows Multiple Document Interface, a flow cytometry application. Build # 05 03-09-1999, copyright 1993–98 Joseph Trotter, The Scripps Research Institute).

2.3. Cell Size Determination

Cell sizes were determined with a Multisizer II electronic particle analyser (Coulter Corporation), with an aperture tube of 30 𝜇m in diameter and a capacity to process 100 𝜇L of the cell suspension in 0.9% NaCl previously filtered through 0.2 𝜇m. Three types of size measurement were obtained after the transformation of the electric pulses generated by the counter: diameter, volume, and revolution surface. Data were analyzed with by AccuComp software version 1.15 (Coulter Corporation). Files were analysed with WinMDI version 2.5 Software (Windows Multiple Document Interface, a flow cytometry application. Build # 05 03-09-1999, copyright 1993–98 Joseph Trotter, The Scripps Research Institute).

2.4. Statistical Theory and Models

The probability model for the biomass distribution of a bacterial culture in exponential phase proposed by Wagensberg et al. [15] was a discrete model with length intervals Δ𝑚. The probability 𝑝(𝑚𝑖) that a bacteria in the culture belongs to a class of biomass 𝑚𝑖 which can be written as 𝑚𝑖=𝑚0+𝑖Δ𝑚, can be expressed as 𝑝𝑚𝑖=1𝑍𝑚𝑖𝑚0𝛾exp𝛽𝑚𝑖,(1) when 𝑚0 represents the smallest possible size required for any bacteria to exist, 𝛾0 and 𝛽0 are parameters, and Z is the appropriate constant to make the sum of all probabilities equal to one.

We note that this model is just a discretisation of a gamma distribution scaled in 𝑚0, that has density 1𝑓(𝑚)=𝑈𝑚𝑚0𝛾exp(𝛽𝑚)𝑚𝑚0,(2) when U (𝑈=exp(𝛽𝑚0)Γ(𝛾+1)𝛽𝛾1) is the necessary constant to make the integral one.

The gamma model does not seem appropriate for our data because this distribution has always a positive skewness (2/(𝛾+1)), whereas in bacteria context some negative skewness have been reported (see below).

Wagensberg et al. [15] deduced the mathematical expression (1) for bacteria biomass distribution using the Maximum Entropy principle. The values of constants 𝛾 and 𝛽 in (1) are determined according to two constraints, the mean value and the maximization of the new born system’s entropy.

One reason to use the skew-Laplace model for flow cytometer and Multisizer data is its maximum entropy property. The entropy of a probability distribution with density 𝑓 is defined as +[𝑓]𝑓ln(𝑥)(𝑥)𝑑𝑥.(3) It is shown in (Kotz et al. [24]), that among all continuous distributions on (,) with a given mean and first absolute moment (centered both at 𝜇), 𝐸[𝑋𝜇] and 𝐸[|𝑋𝜇|], the skew-Laplace distribution provides the largest entropy.

We have calculated the skew-Laplace fits for cell size (obtained by Multisizer II) and scatter measurements (obtained by flow cytometry) from cultures of Gram-positive, Gram-negative, some yeasts and the two naturally occurring aquatic bacterial populations. The methods used to calculate the adequacy of the fit has been described previously (Julià and Vives-Rego [2, 25]). Previous studies have shown that the size distributions obtained by flow cytometer and other methods are not normal (Koch [13], Koch et al. [11], López-Amorós et al. [12], Vives-Rego et al. [14], Vives-Rego et al. [7], Wagensberg et al. [15]). Although other mathematical distributions have been used to assess bacterial size distributions, skew-Laplace distributions have only been tested in bacteria recently (Julià and Vives-Rego [2, 25]).

Given that our data on the tested microorganisms clearly show asymmetrical tails, it is not appropriate to fit the data to the normal distribution.

The skew-Laplace distribution has the following density function with parameters 𝛼>0, 𝛽>0, and 𝜇: 𝑓(𝑥;𝛼,𝛽,𝜇)=𝛼𝛽𝛼+𝛽exp(𝛼(𝜇𝑥)),if𝑥𝜇,𝛼𝛽𝛼+𝛽exp(𝛽(𝑥𝜇)),if𝑥>𝜇.(4) The mean and variance of the skew-Laplace distribution are related to the three parameters (𝜇, 𝛼, and 𝛽) as follows:1Mean𝜇𝛼+1𝛽1,Variance𝛼2+1𝛽2.(5) The parameter 𝜇 is closely related to the mean; in fact, when 𝛼=𝛽 (symmetric case), 𝜇 is the true mean, also known as the “location parameter” which implies that 𝜇 determines the location of the distribution origin. The distribution becomes more asymmetric as 𝛼 differs more pronouncedly from 𝛽. The greater the 𝛼 and 𝛽 values, the more pointed is the distribution. Conversely, lower 𝛼 and 𝛽 values result in a flat distribution. If natural (Neperian) logarithms are applied, we obtain two straight lines with slopes 𝛼 and 𝛽, respectively, ln𝑓(𝑥;𝛼,𝛽,𝜇)=ln𝛼𝛽𝛼+𝛽𝛼𝜇+𝛼𝑥,if𝑥𝜇,ln𝛼𝛽𝛼+𝛽𝛽𝑥+𝛽𝜇,if𝑥>𝜇.(6) This finding provides us with an important tool to verify whether the Laplace distribution is correct. When we plot the frequency curves using a natural logarithmic scale on the vertical axis, we obtain two straight lines if the model is correct. To estimate the parameters of the skew-Laplace distribution, we used the maximum likelihood method (Kotz et al. [24]). As proposed in our previous study (Julià and Vives-Rego [2]), we used two methods to verify the goodness of fit: graphical and numerical. Plots of data quantile versus skew-Laplace quantile (quantile-quantile plot) were obtained. Graphically, the proximity of these plots to the straight-line shows the goodness of fit. To quantify the quality of the skew-Lapace fitting, we calculated the critical size 𝑁crit, proposed by (Fieller et al. [26].) This statistic could be interpreted as the critical sample size, which would be required to detect lack of fit at the 5% level. The critical size 𝑁crit is a statistic based on the chi-square goodness-of-fit test. The 𝑁crit is defined as 𝑁crit=𝜒2𝑘𝑚1;0.95𝑘𝑖=1𝑟𝑖𝑝𝑖̂𝜃2/𝑝𝑖̂𝜃,(7) where 𝑘 represents the number of intervals, 𝑚 the number of estimated parameters, and 𝑟𝑖 and 𝑝𝑖(̂𝜃) are the sample proportion and the estimated skew-Laplace probability for the relevant interval, respectively. We have standardized the procedure to obtain 40 intervals for each sample, the more homogeneous the better. When the maximum likelihood estimation is used, the chi-square goodness-of-fit statistic has between 𝑘1 and 𝑘𝑚1 degrees of freedom (Chernoff and Lehmann [27]). The fact that 𝑁crit is defined for 𝑘𝑚1 degrees of freedom, however, is irrelevant due to the presence of large numbers of intervals (40 in our case) with respect to the number of parameters (3 in our case). All computations were made using MatLab (MathWorks Inc., Natick, MA 01760-2098).

3. Results

3.1. Quality of the Fit and Visual Examination

We used three tools to evaluate the goodness of fit: the value 𝑁crit, the q-q plot and the frequency plot in logarithmic scale. The q-q plot is usual in statistics and represents the empirical quantiles versus theoretical model quantiles. When the fit is good, the q-q plot is nearly a straight line.

The other plot responds to the properties described in Section 2.4, where we demonstrated that if logarithms are applied to these frequencies and the model of skew-Laplace is valid, two straight lines result.

The 𝑁crit values calculated in this paper ranged between 0 and 4307. Such a large range implies that those criteria and circumstances used to determine whether the fit is acceptable or not must be defined. In theory 𝑁crit values may range from 0 to infinite. Obviously large 𝑁crit values indicate goodness of fit to the skew-Laplace distribution, while small values indicate poor goodness of fit. We propose to distribute the studied microorganisms into four classes according to the values of 𝑁crit.(1)For 𝑁crit values higher than 900, the fit to the skew-Laplace distribution is excellent, the quantile-quantile plot showing a straight line, with two straight lines appearing when the frequencies are plotted in logarithmic scale. (2)For values of 𝑁crit between 500 and 900, the fit is also satisfactory, with the quantile-quantile plot showing a nearly straight line, and two straight lines appearing when the frequencies are plotted in logarithmic scale.(3)For values of 𝑁crit between 250 and 500, the fit is rather poor. However, the empirical distribution shape is similar to the skew-Laplace distribution. This can be seen when the frequency curves are plotted using a logarithmic scale on the vertical axis, we then obtain two straight lines except in the case of extreme values. In these cases the fit is deemed acceptable.(4) Finally, values of 𝑁crit between 0 and 250 show that the skew-Laplace distribution is unacceptable.

In Table 1 we have recorded the highest values that have been obtained. Based on our calculations for the strains cultured in batch or chemostat under varying conditions, we concluded not only that SS always fits the skew-Laplace distribution, but also that FS similarly fits the skew-Laplace distribution with the minor exceptions of C. auringiensis and B. subtilis (grown in chemostat). Although the cell diameter assessed by Multisizer fit the skew-Laplace distribution in many cases exceptions were observed (e.g., S. mutans and S. griseus, Table 1). Our initial conclusion is that while the FS and SS cytometric parameters follow the skew-Laplace distribution, this was not always true of the cell diameters. Figure 1 displays one of the best and one of the worst examples of fit vis-à-vis quantile validation. Figure 2 illustrates six examples of the optimal fittings for FS, SS, and cell diameter with skew-Laplace distribution shapes readily apparent, where the symmetry of the fittings is diverse. Some of the obtained fits, resulted nearly symmetrical for the logarithm of the E. coli cell diameter with 𝛼 and 𝛽 proving quite similar (𝛼/𝛽=1.06 for chemostat and 𝛼/𝛽=0.94 for batch). We otherwise, observed a slight asymmetry for the FS of E. coli since the left tail is larger than the right one (negative skewness); in this case 𝛼 is almost half of the 𝛽 value (𝛼/𝛽=0.52 for chemostat and 𝛼/𝛽=0.46 for batch). On the other hand, the asymmetry for the SS of S. aureus, was more pronounced, showing a right tail significant larger than the left one (positive skewness); in this case 𝛼 is 12-fold greater than 𝛽 (𝛼/𝛽=12.85 for chemostat and 𝛼/𝛽=12.56 for batch). The absence of significant skewness differences between the studied parameters from batch and chemostat cultures are independent of the quality of their skew-Laplace distribution fit.

3.2. The Skew-Laplace Fit in Cell Size and Flow Cytometric Scatters

It was found that the cell size data for microscopically measured aquatic bacteria from coastal Cantabric sea water and Tanganyika lake clearly did not fit with the skew-Laplace distribution (data not shown). This strongly suggests that the skew-Laplace fitting is a characteristic only applicable to some microbial axenic cultured populations.

Another remarkable finding is that while in our previous paper (Julià and Vives-Rego [2]), where we only analysed three Gram-negative bacteria, the skew-Laplace fitting of FS was null or poor and in our present study the fitting was acceptable. Such difference may stem from variabilities in the equipment. More specifically, the chamber of the Epics XL used in the present paper was more sensitive and generated more stable signals than the equipment used in [2] that was an Epics Elite. Another interesting aspect is that the fitting of the skew-Laplace distribution with FS is generally better than with the cell diameter, despite the assumption that flow cytometric FS values are related to bacterial size (Shapiro [6]).

The SS of the studied microbes show a strong fitting (frequently better that FS) with either the skew-Laplace or with the log-skew-Laplace distribution. Such generalized mathematical fitting suggests that an underlying biological process is at work. SS values reflect cell granulosity, which in bacteria, stems from the presence of vesicles, vacuoles, and granules of different natures (ribosome, polyphosphates, PHB, glycogen, proteins and others) (Shapiro [6]). The more ribosome and protein per bacteria, the higher is the cell’s metabolic activity, cellular performance, and growth rate. In addition, the higher the growth rate, the higher is the cell concentration in proteins and ribosomes (Schaechter et al. [28]). On the other hand, granulosity caused by intracellular accumulation of reserve compounds such as lipids, starch and glycogen, is normally observed in microbial cells with retarded metabolic activity and slow growth rate (Panikov [29, 30]). Such facts strongly indicate that the metabolic activity of a culture results from different cell types exhibiting diverse metabolic activities and macromolecular content. In this case, the lower the 𝛼 and 𝛽 values, the higher the amplitude of the variation in metabolic activity levels.

In general at the population level, high SS values would imply a metabolically and biologically more active population than those exhibiting lower SS values. However, since we have not observed a linear relationship between increases in SS and the growth rate in chemostat experiments, such a relationship remains unclear. Since the total RNA or the ribosome cellular content is linearly related to specific growth rate, the SS values seem to be subsequently influenced by other particles inside the cell than ribosome, such as granules of lipid, starches, sulphurs, metachromatins, and so forth, (Panikov, [29, 30]). At the initial growth acceleration (e.g., growth rates between zero and 30% of maximum), the increase in ribosome content parallels a decrease in the reserve compounds. Consequently, the total granulosity and SS can remain almost constant since the ribosome increase is counterbalanced by the decrease in other granules. At higher growth rates (50%–100% of the maximum), the ribosome contribution becomes predominant, consequently, the increase in SS under accelerated growth conditions is presumably much more clearly associated with growth rate. Another possible explanation for the nonlinear correlation between the growth rate and SS is that the latter may be essentially associated with polyribosomes, since its intracellular concentration is rather low in slowly growing cells. Whether either of these two possibilities is definitively and linearly linked to SS variations, is a question that must be determined and validated by direct molecular analysis combined with flow cytometry.

In Table 2 we present the evolution along the three incubation times of the parameters resulted from the skew-Laplace fit of FS, SS, and Multisizer values. In this table we only present three microorganisms of different morphology and we omit the log-skew-Laplace fit of FS, SS, and Multisizer values. The data presented in Table 2 come from the same replica for each of the three microorganisms on which the three FS, SS, and Multisizer values were measured at the three incubation times. When the maximum values of 𝑁crit have been reached in another replica or for the fit of log-skew-Laplace distribution, the values reported in Table 2 do not match with those in Table 1. The presented results are only a small part of total data obtained in this study (more than 4000 values considering the replicas). Our conclusive overview of this tremendous amount of data is that there is not a clear nor repetitive trend in the skew-Laplace fit. According to our results, we cannot say that any group of microorganisms (Gram-negative, Gram-positive, or yeast) shows better fits to skew-Laplace distribution. Consequently, the observed differences seem to be the consequence of the intracellular and morphological characteristics of each strain.

4. Discussion

It was not until the work of Barndorff-Nielsen and co-workers (Bagnold and Barndorff-Nielsen [31], Barndorff-Nielsen [32]) that a coherent statistical approach was formulated for the mathematical analysis of particle-size distribution. Skew-Laplace distributions were originally proposed by (Fieller et al. [26]) as a pragmatic alternative to the four-parameter hyperbolic family. Although reliable software is available for fitting hyperbolic distributions, we have ruled out this family as it is too complex and because similarity of distribution does not necessarily mean that the parameters are similar.

Since the skew-Laplace fittings in chemostat cultures are no better than in batch cultures, and since in general their 𝑁crit values are inferior, we have to conclude that the skew-Laplace fitting cannot be linked to the biochemical or morphological heterogeneity of the cultures. This conclusion is supported by the fact that the skew-Laplace distribution clearly does not fit with the cell size of bacterial aquatic populations either from sea water or lake waters. Thus, the skew-Laplace model is an approach applicable to only axenic population studies, irrespective of their heterogeneity level. A plausible biological interpretation of the skew-Laplace fitting is that bacterial cultures share a general mathematical distribution with small, repetitive biological and nonbiological materials.

We found a satisfactory fit in many cases, most of them corresponding to the 6 h of incubation (exponential phase) and for those microorganisms exhibiting low morphological variability. In those cases were we observe a lack of the goodness of fit, the skew-Laplace model was not able to give a satisfactory quantitative measure of the differences among irregular and highly variable morphotypes.

These facts reinforce the general assumption that cells from an axenic culture are inherently heterogeneous in many aspects as recently simulated by Prats et al. [3, 4]. This includes the kinetic properties of the individual cells as shown by the ribosomal and granular density variability when indirectly assessed via SS values. Such heterogeneity is completely overlooked in most studies.

Taking into account the high bacterial diversity observed in bacterial axenic cultures (Vives-Rego et al. [1]), t is likely that due to any environmental change, a fraction of the cell population will have a selective advantage. If so, an axenic culture exposed to various substrates will produce different final populations. Consequently, the biological properties of the resulting cultures will not be identical, despite having originated from the same axenic culture.

Simulations previously reported (Prats et al. [3, 4, 33]) showed a forward shift of the biomass distribution during the lag phase, a maintained stability during the exponential phase and a backwards shift during the transition to stationary phase. This behavior was experimentally observed and validated in an Escherichia coli culture using flow cytometry and particle size analysis measurements (Prats et al. [33]). These simulation results strongly indicate that bacterial cultures exhibit an intrinsic and extrinsic variability that cannot be always and perfectly adjusted to a continuous and deterministic model as the skew-Laplace distribution. Cell size distribution may change as a function of the symmetric (E. coli and others) or asymmetric (yeasts) type of cell, the cell division mechanism, the cell cycle phase (lag, exponential, or stationary) as well as the genetic and environmental factors.

A genome can be accurately duplicated and clone populations can be fully homogeneous if mutations, genetic transfers, and internal genetic recombination do not drive the population towards heterogeneity. These factors are therefore, the main pillars of diversity and evolutionary potential in bacterial populations. A bacterium may express various phenotypes without a difference in genotype due to alterations in the microenvironment.

A practical consequence of this new-found property (the skew-Laplace fit) concerning axenic cultures is that flow cytometric definitions of high granulosity subpopulations would be useful in selecting mutants (experimentally or naturally). Once the high granulosity subpopulation is cytometrically sorted, any genetic process affecting it will be more productive than in those cultures containing both high and low granulosity populations. Spontaneously and naturally induced mutations would also be more effective in exclusively high granulosity subpopulations than in conventionally mixed cultures containing both high and low granulosity populations. Any experimental or natural process within axenic cultures intended to obtain high numbers of mutations will be more successful if applied to a subpopulation with high granulosity, versus that with lower granulosity.

The main advantages of the skew-Laplace approach are: (i) it provides a simple but effective tool for analyzing distribution frequencies; (ii) the resulting graphs can be compared visually quite easily; (iii) the three numerically associated parameters of the graphs (𝜇,𝛼,𝛽) allow easy and rapid comparison of the quantitative differences among similar distributions; (iv) the skew-Laplace approach optimizes the potential of flow cytometric cell sorting since it provides a better mathematical delimitation of small subpopulations for subsequent cell sorting; (v) it can be easily incorporated into the standard software of automatic readers used for cells parameters in general and in flow cytometry in particular; (vi) it enlarges the palette of tools in the field of populations analyses related to microbiology, biotechnology, and eukaryotic clone studies. A final biological interpretation of the fitting is that bacterial axenic cultures share a general mathematical distribution of small, repetitive biological and nonbiological materials. This shared mathematical behavior probably also reflects a general physical law that applies to all small particles, irrespective of whether they have a biological origin.

Acknowledgments

The authors are extremely grateful to Ainhoa Latatu and Juan Iriberri for kindly providing bacterial size data for the coastal Cantabric Sea (Spain); to Samuel Pirlot and Pierre Servais for providing us with the size data for the aquatic bacteria of Lake Tangayika in Africa to Dr. Jaume Comas-Riu (Scientific and Technical Services of the University of Barcelona) for his helpful technical assistance with the flow cytometer and the electronic particle analyzer. The authors thank the referees for their accurate, rigorous, and constructive comments, which have helped them to improve the presentation of their results. This work has been partially supported by Grant MTM2008-06747-C02-01/MTM from Ministerio de Ciencia y Tecnología.