Research Article

Comparative Performance of Creatinine-Based Estimated Glomerular Filtration Rate Equations in the Malays: A Pilot Study in Tertiary Hospital in Malaysia

Table 3

Correlation coefficient (), mean, bias, precision, and accuracy for CGBSA, 4-MDRD, and CKD-EPI formula.

Correlation coefficient ()Mean GFRRange (IQR) valueMean difference (bias)SD of mean bias (precision)Accuracy within
LowerUpper10%30%

Measured GFR42.03917.70111.10
CGBSA0.87740.46716.52115.520.303−1.57310.8029.847.1
4-MDRD0.84835.90214.0098.000.001−6.13712.05813.754.9
CKD-EPI0.85437.23514.00121.000.005−4.80411.69713.749.0

Significantly correlating with .
(Bias: mean difference of estimated GFR and measured GFR; accuracy: percentage of GFR estimates within % of measured GFR; IQR: interquartile range).