Research Article
Thermal Analysis of ZPPR High Pu Content Stored Fuel
Table 5
Summary of calculated fuel temperature results.
| Temperatures, °C | Case | Number of fuel plates | Problem description | Max fuel | Front clam | Cavity door | Bin door | Compare to | Max fuel Temp. diff. from base |
| Fuel placed parallel to front of storage bins—6-inch elements | A | 16 | Base, eps = 0.3 | 186 | 107 | 75 | 39 | Best Est. | Base case |
| 1 | 16 | Base, eps = 0.3 | 219.3 | 146.9 | 87 | 39.6 | Base for | Parameter study | 2 | 16 | Increase eps = 0.8 | 191.6 | 147.7 | 87.4 | 39.6 | Case | Minus 29 | 3 | 16 | Low power | 137.4 | 96.2 | 61.6 | 37.2 | Case | Minus 83 | 4 | 16 | No heat next cavity, high power | 200.2 | 123.4 | 67 | 37.6 | Case | Minus 20 | 5 | 16 | No heat next cavity, low power | 124.3 | 81.7 | 50.7 | 36.2 | Case | Minus 13 | 6 | 16 | Rub mat and Al plate | 224.1 | 147.2 | 87.5 | 39.7 | Case | Plus 4 | 7 | 16 | No thermal radiation | 530 | 392 | 185.8 | 39.5 | Case | Plus 310 | 8 | 6 | Only 6 fuel elements | 182.8 | 110.1 | 58.4 | 36.8 | Case | | 9 | 16 | Cell cooling off | 235.3 | 166.3 | 111.6 | 70.2 | Case | Plus 15 | 10 | 16 | Hi power 35 W | 280.4 | 186.8 | 109.2 | 42.1 | Case | Plus 60 | 11 | 16 | Hi power 35 W and cell cooling off | 292 | 202 | 130.5 | 72.6 | Case | Plus 72 |
| Fuel placed perpendicular to front of storage bins—8-inch elements | 12 | 12 | 8-inch fuel | 210 | 146.9 | 87 | 39.6 | Case | Minus 10 |
|
|