Table of Contents
International Journal of Nuclear Energy
Volume 2014 (2014), Article ID 410715, 9 pages
http://dx.doi.org/10.1155/2014/410715
Research Article

Simulation of the Westinghouse AP1000 Response to SBLOCA Using RELAP/SCDAPSIM

1Nuclear & Radiation Engineering Department, Faculty of Engineering, Alexandria University, Alexandria 21544, Egypt
2Centre for Nuclear Energy Technology, University of Manchester, Manchester, M13 9PL, UK
3Innovative Systems Software (ISS), Ammon, ID 83406, USA

Received 20 August 2014; Revised 23 November 2014; Accepted 23 November 2014; Published 16 December 2014

Academic Editor: Arkady Serikov

Copyright © 2014 Ayah Elshahat et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. AP1000 Nuclear Power Plant BAT Assessment, Westinghouse Electric Company, 2011.
  2. G. Saiu and M. L. Frogheri, AP1000 Nuclear Power Plant Overview, ANSALDO Energia—Nuclear Division, Genoa, Italy.
  3. A. E. Abouelnaga, A. Metwally, N. Aly, M. Nagy, and S. Agamy, “Assessment the safety performance of nuclear power plants using Global Safety Index (GSI),” Nuclear Engineering and Design, vol. 240, no. 10, pp. 2820–2830, 2010. View at Publisher · View at Google Scholar · View at Scopus
  4. “PCTran for PWR and AP1000,” Micro Simulation Technology, 2006.
  5. http://www.relap.com.
  6. C. M. Allison and J. K. Hohorst, Role of RELAP/SCDAPSIM in Nuclear Safety, Science and Technology of Nuclear Installations, 2010.
  7. L. J. Siefken, C. M. Allison, and J. K. Hohorst, “RELAP/SCDAPSIM/MOD3.5—improvements resulting from QUENCH and PARAMETER bundle heating and quenching experiments,” in Proceedings of the 8th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids, Dubrovnik, Croatia, May 2010.
  8. Westinghouse AP1000 Design Control Document, Westinghouse Electric Company, 2004.
  9. T. L. Schulz, “Westinghouse AP1000 advanced passive plant,” Nuclear Engineering and Design, vol. 236, no. 14–16, pp. 1547–1557, 2006. View at Publisher · View at Google Scholar · View at Scopus
  10. “Westinghouse AP1000 Design Control Document, ML11171A500, Rev. 19, Chapter 15: Accident Analyses,” 2011.
  11. R. C. D. Team, “RELAP5/MOD3.3 Code Manual: NUREG/CR-5535”.
  12. “NOTRUMP, a nodal transient small-break and general network code,” Tech. Rep. WCAP-10079-P-A, 1985.
  13. Chapter 21. Testing and Computer Code Evaluation, “Final Safety Evaluation Report Related to Certification of the AP1000 Standard Design,” Initial Report NUREG-1793.