Enhancements in the absorbed pump powers, the laser output powers, and the standard tracking errors achieved by the truncated cavity. Comparisons are made with the 3D-CPC-2D-CPC cavity. The positive values in bold signify the enhancement in the powers in percentage. The negative values in italic represent the reduction in standard 2 mrad tracking errors in percentage.

Diameter (mm)3 mm4 mm5 mm6 mm

P A B S . enhancement (%) + 𝟓 . 𝟐 + 𝟐 . 𝟏 + 𝟎 . 𝟒 + 𝟏 . 𝟗
Standard tracking error (%) 1.2 2.5 3.2 3.6
P M - M enhancement (%) + 𝟏 𝟐 . 𝟎 + 𝟖 . 𝟔 + 𝟕 . 𝟏 + 𝟏 𝟏 . 𝟎
Standard tracking error (%) 1.6 3.5 4.9 5.9
P T E M 0 0 enhancement (%) + 𝟐 𝟗 . 𝟎 + 𝟒 𝟐 . 𝟓 + 𝟔 𝟐 . 𝟏 + 𝟕 𝟐 . 𝟕