Research Article

On the Performance of Hybrid PV/Unitized Regenerative Fuel Cell System in the Tropics

Table 3

Summary of the selected day measured and simulation results.

System SimulatedMeasured

Solar input 4.084.08kWh/m2
PV output0.830.78kWh
PV efficiencya10.39.7%
User load 0.370.37kWh
PV to loadb28.8531.43%
Load powered by PVc65.2666.94%
FCM power 0.130.12kWh
FCM operating hours 77hr
Total H2 consumedd0.250.27kWh
FCM energy efficiencye50.145.35%
ELM power 0.460.51kWh
ELM operating hours99hr
Total H2 produced 0.390.35kWh
ELM energy efficiencyf 84.4868.98%
Total system Efficiencyg4.554.55%
Round trip efficiencyh42.3131.28%

aPV output to the solar input.
b(Load − Fuel cell mode power)/PV output.
c(Load − Fuel cell mode power)/load.
dBased on HHV for hydrogen.
eFuel cell mode power to the hydrogen consumed.
fHydrogen produced to the electrolyzer mode power.
gLoad to the solar input.
hFuel cell mode efficiency and electrolyzer mode efficiency.