Research Article
Applying a Cerebellar Model Articulation Controller Neural Network to a Photovoltaic Power Generation System Fault Diagnosis
Table 6
Test data under 300–1000 W/m2 irradiation and PV module surface temperatures between 51 and 60°C.
| Test no. | (W) | (V) | (A) | (V) | Temperature (°C) | Irradiation (W/m2) | Known fault type |
| 1 | 834.4 | 293.69 | 2.84 | 358.83 | 51.5 | 300 | PF1 | 2 | 1146.19 | 297.99 | 3.85 | 364.3 | 52.5 | 400 | PF1 | 3 | 1343.63 | 274.46 | 4.9 | 368.22 | 53.5 | 500 | PF2 | 4 | 1627.07 | 275.99 | 5.9 | 371.31 | 54.5 | 600 | PF2 | 5 | 1689.67 | 244.75 | 6.9 | 373.75 | 55.5 | 700 | PF3 | 6 | 1934.57 | 243.17 | 7.96 | 375.79 | 56.5 | 800 | PF3 | 7 | 1872.46 | 210.42 | 8.9 | 377.46 | 57.5 | 900 | PF4 | 8 | 2077.41 | 208.71 | 9.95 | 378.86 | 58.5 | 1000 | PF4 | 9 | 726.03 | 255.95 | 2.84 | 312.88 | 59.5 | 300 | PF5 | 10 | 1021.06 | 263.33 | 3.88 | 324.53 | 51.5 | 400 | PF5 | 11 | 1134.87 | 231.04 | 4.91 | 287.06 | 52.5 | 500 | PF6 | 12 | 1374.59 | 232.48 | 5.91 | 289.46 | 53.5 | 600 | PF6 | 13 | 1380.6 | 200.41 | 6.89 | 249.74 | 54.5 | 700 | PF7 | 14 | 1580.05 | 198.79 | 7.95 | 251.09 | 55.5 | 800 | PF7 | 15 | 2158.96 | 241.32 | 8.95 | 336.22 | 56.5 | 900 | PF8 | 16 | 2393.71 | 239.48 | 10 | 337.47 | 57.5 | 1000 | PF8 | 17 | 577.06 | 200.23 | 2.88 | 313.59 | 58.5 | 300 | PF9 | 18 | 791.4 | 203.64 | 3.89 | 318.54 | 59.5 | 400 | PF9 | 19 | 1017.84 | 208.04 | 4.89 | 287.63 | 51.5 | 500 | PF10 | 20 | 1232.58 | 209.42 | 5.89 | 290.01 | 52.5 | 600 | PF10 |
|
|