Research Article

Assessment of the Operating Temperature of Crystalline PV Modules Based on Real Use Conditions

Table 2

Tabular data of I-V curve of the Kyocera KC175GHT-2 at different solar irradiance.

Rad. (W/m2)100090080070060050040030020010050

(W)175.1156.8138.5120.3102.384.566.849.332.115.57.4
(V)23.623.523.323.223.022.822.522.221.720.920.1
(A)7.46.75.95.24.43.73.02.21.50.70.4
(V)29.229.128.928.828.628.328.127.727.226.325.5
(A)8.17.36.55.74.94.03.22.41.60.80.4