Research Article
Study on a Mid-Temperature Trough Solar Collector with Multisurface Concentration
Table 1
Technical specifications of instruments used in experimental setup.
| Instrumentation | Range | Accuracy |
| Average wind speed measurement chip/Kanomax-KA22 | 0.1–50 m/s | ±0.2% | Liquid turbine flow meter/LWYC-15 | 0–20 L/min | ±0.5% | 32-channel digital data-recording/JLS-XMT | −200–600°C | ±0.5% | Temperature measuring sensors/Pt100 | −20–300°C | ±0.1°C | High temperature oil circulation pump/120 W |
0–8 L/min | | Tracking motor/25 W | | |
|
|