Research Article
Analysis of Power Loss for Crystalline Silicon Solar Module during the Course of Encapsulation
Table 4
The relationship between the power of solar module and thickness of ribbon.
| Module | (V) | (A) | FF (%) | (W) | (V) | (A) | Dimension of ribbon (mm2) |
| 1 | 44.90 | 5.59 | 75.87 | 190.37 | 36.40 | 5.23 | 1.6 × 0.14 | 2 | 45.01 | 5.60 | 75.88 | 191.26 | 36.43 | 5.25 | 1.6 × 0.15 | 3 | 45.03 | 5.60 | 76.01 | 191.68 | 36.51 | 5.25 | 1.6 × 0.16 | 4 | 45.06 | 5.61 | 76.17 | 192.56 | 36.60 | 5.26 | 1.6 × 0.17 | 5 | 45.08 | 5.62 | 76.21 | 193.09 | 36.64 | 5.27 | 1.6 × 0.18 | 6 | 45.14 | 5.63 | 76.27 | 193.83 | 36.71 | 5.28 | 1.6 × 0.19 | 7 | 45.20 | 5.63 | 76.31 | 194.20 | 36.78 | 5.28 | 1.6 × 0.20 | 8 | 45.19 | 5.64 | 76.19 | 194.19 | 36.71 | 5.29 | 1.6 × 0.21 | 9 | 45.20 | 5.64 | 76.17 | 194.19 | 36.71 | 5.29 | 1.6 × 0.22 |
|
|
Test conditions: 1 kW/m2 irradiance, 25°C module temperature, and AM1.5 global spectrum.
|