Research Article
Design, Development, and Analysis of a Densely Packed 500x Concentrating Photovoltaic Cell Assembly on Insulated Metal Substrate
Table 7
Power losses breakdown in the conductive pattern.
| Component code | Geometry | Power losses per piece [W] | Number of repetition in 144-cell design | Total power losses [W] |
| C1 | | 0.013 | 2 | 0.026 |
| C2 | | 0.077 | 132 | 10.202 |
| C3 | | 0.014 | 10 | 0.140 |
| C4 | | 0.067 | 2 | 0.134 |
|
|