Research Article

Heuristic Storage System Sizing for Optimal Operation of Electric Vehicles Powered by Photovoltaic Charging Station

Table 2

Results of the statistical assessment of active power in PV and CSP in winter and spring.

Spring dayA dayAn average day
PVCSPPVCSP

Measurement values per day86,40086,40086,40086,400
Installed power in kW116.6110.8116.6110.8
Arithmetic average in kW16.865.4123.463.97
Standard deviation in kW25.2811.2328.137.65
Variance in kW2639.23126.06791.3258.58
Maximum power in kW100.6154.4185.2741.12
Minimum power in kW0.000.230.000.23
Maximum in kW/s33.0812.926.623.02
Energy in kWh404.72129.85563.1195.18
Energy relation based on load3.121.005.921.00

Winter dayA dayAn average day
PVCSPPVCSP

Measurement values per day86,40086,40086,40086,400
Installed power in kW116.6110.8116.6110.8
Arithmetic average in kW2.845.701.293.58
Standard deviation in kW5.908.692.364.69
Variance in kW234.8075.525.5922.00
Maximum power in kW51.9443.3712.9725.41
Minimum power in kW0.000.410.000.46
Maximum in kW/s5.776.171.151.98
Energy in kWh68.26136.8830.8985.88
Energy relation based on load0.501.000.361.00