Research Article

Evaluation of Shunt Losses in Industrial Silicon Solar Cells

Table 3

Parameters extracted from the experimental dark curves and manufacturer’s data sheet by analytical method for the nonshunted cells (A, B, C, and D) and shunted cells (1, 2, 3, 4, and 5) considered for study.

Cell [A] [Ω] [Ω]

A1.1732.950.014
B1.1318.640.009
C1.43149.110.019
D1.1156.550.005
11.224.30.017
21.163.70.011
31.334.10.018
41.166.420.014
51.142.850.005