Research Article

Design of a 25 MWe Solar Thermal Power Plant in Iran with Using Parabolic Trough Collectors and a Two-Tank Molten Salt Storage System

Table 1

The main geometrical and optical parameters of a collector.

Aperture width (m)6.64Outer dimension of a glass cover (cm)7.0
Inner dimension of a thermal pipe (cm)3.5Glass cover emissivity0.9
Outer dimension of a thermal pipe (cm)4.2Receiver tube (pipe) emissivity0.2
Inner dimension of a glass cover (cm)6.7Optical efficiency0.8