Research Article
Design of a 25 MWe Solar Thermal Power Plant in Iran with Using Parabolic Trough Collectors and a Two-Tank Molten Salt Storage System
Table 1
The main geometrical and optical parameters of a collector.
| Aperture width (m) | 6.64 | Outer dimension of a glass cover (cm) | 7.0 | Inner dimension of a thermal pipe (cm) | 3.5 | Glass cover emissivity | 0.9 | Outer dimension of a thermal pipe (cm) | 4.2 | Receiver tube (pipe) emissivity | 0.2 | Inner dimension of a glass cover (cm) | 6.7 | Optical efficiency | 0.8 |
|
|