Research Article
Comparison of Turkey’s Geographical Regions in terms of Stand-Alone PV System Design and Cost Parameters
Table 1
Constant values of SAPV system components.
| Life cycle (years) | System | 25 | Module | 25 | Battery | 10 | Charge regulator | 15 |
| Operating period (months) | 12 | Annually operating days | 365 | Annually operating hours | 8760 | Load power (VA) | 1000 | Module current (A) | 22.5 | Battery voltage (V) | 12 | Battery capacity (Ah) | 110 |
| Efficiency | Battery | 0.95 | Transmission line | 0.98 |
| Unit price ($) | Module | 200 | Battery | 150 | Charge regulator | 100 |
| Daily load demand | (Ah/day) | 2148.23 | (kVAh/day) | 25.78 |
| Replacement numbers | Module | 0 | Battery | 2 | Charge regulator | 1 |
| Annual inflation rate | 0.12 | Annual discount rate | 0.18 |
|
|
These values vary according to the selected scenario. The values in the table are given for the whole year scenario.
|