The electrical parameters for module 8 before shipments and after one year of operation.

Module 8Voc (V)Isc (A)Vm (V)Im (A)Rsh (Ω) (W)

Before shipments44.965.7336.585.38398.23196.81
After one year of operation44.925.6236.485.22385.45193.28
Degradation rate (%)0.091.920.272.973.211.79

Test conditions: 1 kW/m2 irradiance, 25°C module temperature and AM1.5 global spectrum.