Research Article

Experimental Study on a Forced-Circulation Loop Thermosiphon Solar Water Heating System

Table 6

Daily experimental results (arranged by date).

Date (D/M) (°C) (°C) (°C) (°C) (MJ/m2·day)

17/127.430.322.85.315.7900.500
19/127.928.420.57.514.0990.504
23/127.829.721.95.915.3260.495
14/0310.842.531.717.620.3560.540
24/0311.250.339.117.324.0850.561
25/0311.549.738.222.720.5180.582
26/0313.748.835.121.021.5730.563
01/0415.452.236.822.423.0580.552
03/0414.448.734.417.622.3320.533
05/0415.346.931.522.019.5270.558
06/0416.046.430.324.318.2500.575
07/0417.547.830.324.418.5880.564