Daily experimental results (arranged by date).
| Date (D/M) | (°C) | (°C) | (°C) | (°C) | (MJ/m2·day) | |
| 17/12 | 7.4 | 30.3 | 22.8 | 5.3 | 15.790 | 0.500 | 19/12 | 7.9 | 28.4 | 20.5 | 7.5 | 14.099 | 0.504 | 23/12 | 7.8 | 29.7 | 21.9 | 5.9 | 15.326 | 0.495 | 14/03 | 10.8 | 42.5 | 31.7 | 17.6 | 20.356 | 0.540 | 24/03 | 11.2 | 50.3 | 39.1 | 17.3 | 24.085 | 0.561 | 25/03 | 11.5 | 49.7 | 38.2 | 22.7 | 20.518 | 0.582 | 26/03 | 13.7 | 48.8 | 35.1 | 21.0 | 21.573 | 0.563 | 01/04 | 15.4 | 52.2 | 36.8 | 22.4 | 23.058 | 0.552 | 03/04 | 14.4 | 48.7 | 34.4 | 17.6 | 22.332 | 0.533 | 05/04 | 15.3 | 46.9 | 31.5 | 22.0 | 19.527 | 0.558 | 06/04 | 16.0 | 46.4 | 30.3 | 24.3 | 18.250 | 0.575 | 07/04 | 17.5 | 47.8 | 30.3 | 24.4 | 18.588 | 0.564 |
|
|