Period (W/m. °C) (W/m. °C) (g/m3) (J/kg·K) (g/m3) (J/kg·K)Curvature (m−1)Thermal diffusion coefficient of gas (m2/s)Thermal diffusion coefficient of liquid (m2/s)CaseλΔAΔliquid (K)AΔgas (K)Positive heat flux peak (W/m2)Negative heat flux peak (W/m2)

1002.42614182001006.430.21.20227E − 050.014354067a2.479339−76.9401−118.4243537262−3421
1000.02420.6100041821.2251006.430.21.96289E − 051.43472E − 07b24.79339−54.1293−136.500153319−6358
1000.02420.0610041821.2251006.430.21.96289E − 051.43472E − 07c2.479339−77.3138−118.6228
1000.02420.06100041821.2251006.430.21.96289E − 051.43472E − 07d2.479339−77.3147−118.6212
50.02420.6100041821.2251006.430.24.72384E − 051.43472E − 07e24.79339−69.4986−140.8545207836−145931
1002420.6100041821.2251006.430.20.1962888831.43472E − 07f0.002479−181.6578−44.4312
1000.2420.6998.241821.2251006.430.20.0001962891.43472E − 07g2.479339−77.2963−118.6027
1000.2420.6100041821.2251006.430.20.0001962891.43472E − 07h2.479339−77.2933−118.587659011−5426
1002.420.6100041821.2251006.430.20.0001962891.43472E − 07i0.247934−142.0084−69.118976499−4367
1000.02420.6100041821.2251006.430.24.72384E − 061.43472E − 07i24.79339−100.7039−100.057266164−6202
150.02420.6100041821.2251006.430.24.72384E − 061.43472E − 07k24.79339−61.4455−141.9224122696−74977
50.02420.6100041821.2251006.430.24.72384E − 061.43472E − 07l24.79339−92.7734−85.5599