Research Article

Preliminary Estimate of Coriolis Force of Vapor Flow in Rotating Heat Pipes Based on Analytical Solution

Table 1

Calculating parameters for the specific case.

Parameter/unitValueParameter/unitValue

T/°C50n/rpm3000
hfg/kJ/kg151.82Ur/m/s0.005
ρv/kg/m366.27q/W/cm25