Research Article

A New Multilevel Inverter Topology for Grid-Connected Photovoltaic Systems

Table 3

Comparison of systems.

GCPSDMPC and basic CHB-based GCPS [7]DMPC and topology in [9] based on GCPS [10]Novel H-bridge and DMPC-based GCPSProposed topology and DMPC-based GCPS
Feature

Grid current harmonics (%)1.5–22.7–3.12.5–2.73.2
Output voltage harmonics (%)28–3029–3624–3222
Total power extracted during 0 <  < 0.4 s (W)623.50613618623.25
Total power extracted during 0.4 <  < 0.8 s (W)543542542542.7
Total power extracted during 0.8 <  < 1.2 s (W)462385395462.65
Total power extracted during 1.2 <  ≤ 1.6 s (W)456.9383391.5456.95
Number of switches for 7-level MLI129610
(%)83899695