Research Article
Analyzing the Off-Grid Performance of the Hybrid Photovoltaic/Diesel Energy System for a Peripheral Village
Table 9
Different architectures of energy sources and their performance for the full-option scenario.
| Architecture | Initial cost ($) | NPC ($) | COE ($) | Fuel cost ($/yr) | Excess electricity (%) | Carbon dioxide emission (kg/yr) |
| PV-Gen-Bat. | 219,058 | 1.26M | 0.369 | 47954 | 10.3 | 163,019 | PV-Gen | 73065 | 1.47M | 0.432 | 68462 | 4.87 | 232,738 | Gen | 48000 | 1.48M | 0.434 | 71048 | 1.89 | 241,528 | Gen-Bat. | 48841 | 1.48M | 0.434 | 71048 | 1.89 | 241,528 | PV-Bat. | 782,441 | 1.64M | 0.480 | 0.0000 | 23 | 0000000 |
|
|