Research Article

Numerical Performance Investigation of Parabolic Dish Solar-Assisted Cogeneration Plant Using Different Heat Transfer Fluids

Table 2

Comparison table for three HTFs at three inlet temperature levels.

 K
 K
 kg/sec
sCO2WaterTherminol VP1

(kW)389840914013
(kW)110411591137
(kW)719.2754.8740.4

 K
 K
kg/sec
sCO2WaterTherminol VP1

(kW)351035993610
(kW)994.310201023
(kW)647.6664666.1

 K
 K
 kg/sec
sCO2WaterTherminol VP1

(kW)310131703186
(kW)878.5898902.5
(kW)572.1585587.8