Research Article
Numerical Performance Investigation of Parabolic Dish Solar-Assisted Cogeneration Plant Using Different Heat Transfer Fluids
Table 2
Comparison table for three HTFs at three inlet temperature levels.
| K K kg/sec | sCO2 | Water | Therminol VP1 |
| (kW) | 3898 | 4091 | 4013 | (kW) | 1104 | 1159 | 1137 | (kW) | 719.2 | 754.8 | 740.4 |
| K K kg/sec | sCO2 | Water | Therminol VP1 |
| (kW) | 3510 | 3599 | 3610 | (kW) | 994.3 | 1020 | 1023 | (kW) | 647.6 | 664 | 666.1 |
| K K kg/sec | sCO2 | Water | Therminol VP1 |
| (kW) | 3101 | 3170 | 3186 | (kW) | 878.5 | 898 | 902.5 | (kW) | 572.1 | 585 | 587.8 |
|
|