Research Article

Multicriteria Decision Analysis for Renewable Energy Integration Design: For an Institutional Energy System Network

Table 4

HOMER optimization result for energy production.

ConfigurationPV production (kWh/yr.)Wind production (kWh/yr.)DG production (kWh/yr.)Grid purchases (kWh/yr.)Grid sales (kWh/yr.)Grid net purchases (kWh/yr.)Total electrical production (kWh/yr.)Diesel (L/yr.)DG hours (hr./yr.)

G-PV-W31,60053,98102,97,9547762,97,1783,83,53600
G-W053,98103,26,0934743,25,6193,80,07400
G-PV31,600003,51,15903,51,1593,82,76000
G0003,79,59903,79,5993,79,59900
G-DG-PV-W31,60053,98149,9392,50,4983,2592,47,2393,86,01825,8021,156
G-DG-W053,98149,9392,77,1851,5052,75,6793,81,10425,8021,156
G-DG-PV31,600049,9393,02,1028823,01,2203,83,64125,8021,156
G-DG0049,9393,29,9062463,29,6603,79,84525,8021,156