Research Article
Towards a Smart Encapsulation System for Small-Sized Electronic Devices: A New Approach
Table 2
Experimental setup for each model analyte.
| Model analyte | Detection by | Content of chamber 1 | Content of chamber 2 |
| Glucose | Amperometry | 100 μL glucose solution (1 M) 5 μL ferrocenecarboxylic acid (10 mg/mL) 1895 μL 150 mM PBS buffer (pH 7.46) | 10 μL glucose oxidase (150 mg/mL) 5 μL ferrocenecarboxylic acid (10 mg/mL) 1985 μL 150 mM PBS buffer (pH 7.46) |
| Horseradish peroxidase | TMB reaction assay | 2000 μL peroxidase (1 mg/mL) in citric buffer (pH 4.43) | 2000 μL citric buffer (pH 4.43) |
| Polystyrene (PS) beads | Flow cytometry | Polystyrene beads Ø 1.4 μm = 1.4 * 109/mL Ø 4.2 μm = 4.9 * 107/mL Ø 20.0 μm = 1.1 * 105/mL in 2000 μL isotonic buffer | 2000 μL isotonic buffer |
|
|