Research Article

Competitive Fixed-Bed Adsorption of Pb(II), Cu(II), and Ni(II) from Aqueous Solution Using Chitosan-Coated Bentonite

Table 3

Column adsorption data and parameters of ternary metal solution of Pb(II), Cu(II), and Ni(II) at different bed heights with initial metal concentration of 100 mg/L and flow rate of 0.6 mL/min.

(cm)Metal (mg/L·hr) (min) (min) (mL)MTZ (cm) (mg/g) (mg/g)

1.0Pb(II)0.20117.585402160.789.4724.58
Cu(II)0.2298.574801920.798.10
Ni(II)0.2277.194801920.847.01

2.0Pb(II)0.13338.198703481.2210.6526.67
Cu(II)0.15273.767803121.308.70
Ni(II)0.19202.836302521.367.32

3.0Pb(II)0.07406.6815606242.2211.4728.13
Cu(II)0.07344.0714405762.308.76
Ni(II)0.08283.2313805522.307.91