Research Article

Competitive Fixed-Bed Adsorption of Pb(II), Cu(II), and Ni(II) from Aqueous Solution Using Chitosan-Coated Bentonite

Table 4

Column adsorption data of ternary metal solution of Pb(II), Cu(II), and Ni(II) at different initial metal concentration with bed height of 2.0 cm and solution flow rate of 0.4 mL/min.

(mg/L)Metal (mg/L·hr) (min) (min) (mL)MTZ (cm) (mg/g) (mg/g)

50Pb(II)0.03794.5720408161.1111.5330.74
Cu(II)0.03618.9120408161.1510.12
Ni(II)0.03482.5818607441.369.09

150Pb(II)0.28322.947803121.1714.3134.90
Cu(II)0.29325.077202881.1010.84
Ni(II)0.32221.066302521.309.75

200Pb(II)0.51268.216002401.2213.4935.92
Cu(II)0.53243.525702281.3412.14
Ni(II)0.50172.305402161.4810.29