Research Article

A Kinetic and Mechanismic Study of Plasma-Induced Degradation of Monochloropropionic Acids in Water by Means of Anodic Contact Glow Discharge Electrolysis

Table 1

Elemental yields of products from CGDE of 3-MCPA.

Time (min)3-MCPA conversion (%)ChlorineCarbon
ClMCANDMCAPDAOxalic acidFormic acidICND

00000000000
302724032522710
6045421338331514
9055482439432114
120595332310542711
15064575241144327
18068598161235375
210746310181335404
240766510181436441

: 5.0 mmol/L; inorganic carbon; not determined.