Research Article

Dynamic Response in Transient Operation of a Variable Geometry Turbine Stage: Influence of the Aerodynamic Performance

Table 2

Repeatability uncertainty of the bench.

Quantity 95% confidence range % of ref. conditions

±0.5 g/s 0.5%
ω±50 rad/s 0.5%
±0.003 0.2%