Research Article
Study of High Efficiency Flow Regulation of VIGV in Centrifugal Compressor
Table 2
Mass flow, the mass flow rate change ratio, and efficiency at 60° setting angle.
| Profile | Summer | Winter | Mass flow (kg/s) | Mass flow change ratio (%) | Efficiency (%) | Mass flow (kg/s) | Mass flow change ratio (%) | Efficiency (%) |
| Original | 13.265 | 0 | 87.116 | 23.838 | 0 | 84.285 | 0008 | 11.616 | −12.43 | 84.644 | 22.6 | −5.19 | 83.773 | 0012 | 12.7 | 4.24 | 87.376 | 24.271 | 1.82 | 84.903 | 0018 | 13.92 | 4.94 | 88.074 | 25.2 | 5.71 | 86.000 | 2412 | 13.031 | −1.76 | 87.057 | 23.617 | −0.927 | 84.207 | 4412 | 11.8 | −11.04 | 86.444 | 22.874 | −4.04 | 83.504 | 6412 | 11.49 | −13.38 | 85.763 | 22.4 | −6.03 | 83.084 | 6408 | 10.01 | −24.54 | 80.740 | 21.411 | −10.18 | 81.580 | 6418 | 13.856 | 4.46 | 87.758 | 25.162 | 5.55 | 84.526 | 6312 | 12.11 | −8.71 | 84.607 | 22.52 | −5.53 | 82.207 | 6512 | 10.95 | −17.45 | 87.821 | 22.016 | −7.64 | 85.021 |
|
|