Research Article

Study of High Efficiency Flow Regulation of VIGV in Centrifugal Compressor

Table 2

Mass flow, the mass flow rate change ratio, and efficiency at 60° setting angle.

ProfileSummerWinter
Mass flow (kg/s)Mass flow change ratio (%)Efficiency (%)Mass flow (kg/s)Mass flow change ratio (%)Efficiency (%)

Original13.265087.11623.838084.285
000811.616−12.4384.64422.6−5.1983.773
001212.74.2487.37624.2711.8284.903
001813.924.9488.07425.25.7186.000
241213.031−1.7687.05723.617−0.92784.207
441211.8−11.0486.44422.874−4.0483.504
641211.49−13.3885.76322.4−6.0383.084
640810.01−24.5480.74021.411−10.1881.580
641813.8564.4687.75825.1625.5584.526
631212.11−8.7184.60722.52−5.5382.207
651210.95−17.4587.82122.016−7.6485.021