Research Article

Comparison of PMAC Machines for Starter-Generator Application in a Series Hybrid-Electric Bus

Table 2

Comparison of concentrated versus distributed windings machine.

ā€ƒ Concentrated Distributed
ā€ƒ windings windings

Copper losses (pu) 0.03 0.038
Copper weight (kg) 1.6 2.2
End-turns copper % 25 46
Fill factor (%) 72 61