Research Article

Comparison of PMAC Machines for Starter-Generator Application in a Series Hybrid-Electric Bus

Table 9

Summary of losses for the two machines.

Parameter Analytical Simulated

SPP = 1/2
Speed (RPM) 6000 6000
Power factor 0.97 0.97
(pu) 2.2 2.0
168 211
131 156
95 130
394 471
Efficiency (%) 93 92

SPP = 2/7
Speed (RPM) 6000 6000
Power factor 0.97 0.97
(pu) 1.4 1.3
(W) 182 230
(W) 107 139
[W] 132 142
(W) 391 511
Efficiency (%) 94 91