Sample point (SP)Dry density (g/cc)OMC (%)Measured thermal resistivityCalculated thermal resistivity% difference

11.8515.050.1063.9921.71
21.9216.256.2056.210.018
31.8013.069.8473.334.76
41.8415.434.0752.6135.24
51.7314.066.5481.2218.07
61.9314.067.9975.8110.32
71.8813.051.1567.4424.15
81.8113.051.1864.4320.56
91.8915.042.2148.4312.84
101.9113.071.8872.130.35

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19.