Research Article

In Situ Determination of Thermal Resistivity of Soil: Case Study of Olorunsogo Power Plant, Southwestern Nigeria

Table 6

Comparison of calculated and measured thermal resistivity.

Sample point (SP)Dry density (g/cc)OMC (%)Measured thermal resistivityCalculated thermal resistivity% difference

11.8515.050.1063.9921.71
21.9216.256.2056.210.018
31.8013.069.8473.334.76
41.8415.434.0752.6135.24
51.7314.066.5481.2218.07
61.9314.067.9975.8110.32
71.8813.051.1567.4424.15
81.8113.051.1864.4320.56
91.8915.042.2148.4312.84
101.9113.071.8872.130.35