Research Article

Titrimetric and Spectrophotometric Assay of Ganciclovir in Pharmaceuticals Using Cerium(IV) Sulphate as the Oxidimetric Agent

Table 4

Method robustness and ruggedness expressed as intermediate precision (% RSD).
(a) Titrimetry

RobustnessRuggedness
Parameter altered
GNC taken, μg m−1Volume of H2SO4* (%RSD) ( 𝑛 = 3 )Reaction time* (%RSD) ( 𝑛 = 3 ) Interanalysts, (%RSD) ( 𝑛 = 4 ) Interburettes, (%RSD) ( 𝑛 = 4 )

3.01.562.021.101.32
6.01.321.421.591.53
9.01.651.112.501.25

(b) Spectrophotometry

RobustnessRuggedness
Parameter altered
GNC taken, μg m−1Volume of p-DMAB* (%RSD) ( 𝑛 = 3 )Reaction time* (%RSD) ( 𝑛 = 3 ) Interanalysts, (%RSD) ( 𝑛 = 4 ) Intercuvetts, (%RSD) ( 𝑛 = 4 )

2.01.562.081.151.32
4.01.321.401.291.53
6.01.651.122.101.25

*Volumes of 5 M H2SO4 varied were 5 ± 1  mL, and reaction times were 1 5 ± 1  min.
*Volumes of p-DMAB varied were 1 ± 0 . 1  mL, and reaction times were 1 5 ± 1  min.