Research Article

Heating and Efficiency Comparison of a Fischer-Tropsch (FT) Fuel, JP-8+100, and Blends in a Three-Cup Combustor Sector

Table 3

Flame temperature differences (°F) for (P,T)inlet = [225 psia (1.55 MPa), 790°F (694 K)].

FuelF/A
3%4%5%

FT—JP-80.01073 (41)107 (59)71 (39)
0.01594 (52)84 (47)63 (35)
0.02034 (19)105 (58)90 (50)

50 : 50—JP-80.01055 (31)90 (50)33 (18)
0.01543 (24)41 (23)52 (29)
0.020−3 (−2)42 (23)70 (39)

Values of ΔT in parenthesis are in Kelvins.