Research Article

Method Development and Validation for the Simultaneous Determination of Fexofenadine Hydrochloride and Montelukast Sodium in Drug Formulation Using Normal Phase High-Performance Thin-Layer Chromatography

Table 2

Intraday and interday precision of FEX and MTKT ( š‘› = 6 ).

DrugConc. (ng spotāˆ’1)RepatabilityIntermediate precision
Found conc. Ā± SD% RSDSEFound conc. Ā± SD% RSDSE

FEX2400 2 3 9 9 . 9 1 Ā± 1 2 . 4 1 0.525.08 2 4 0 0 . 6 9 Ā± 1 7 . 7 5 0.747.24
7200 7 2 0 4 . 8 4 Ā± 1 5 . 5 3 0.226.36 7 2 0 5 . 0 2 Ā± 8 . 7 2 0.123.57
10800 1 0 7 9 9 . 4 6 Ā± 1 0 . 7 3 0.094.39 1 0 7 9 7 . 6 7 Ā± 2 7 . 9 5 0.2611.41

MTKT200 2 0 0 . 5 0 Ā± 1 . 4 9 0.740.61 2 0 1 . 3 2 Ā± 0 . 9 6 0.470.39
600 6 0 1 . 7 8 Ā± 1 . 1 7 0.19 0.47 6 0 0 . 5 6 Ā± 0 . 7 2 0.110.29
900 9 0 0 . 6 5 Ā± 0 . 7 5 0.080.30 9 0 0 . 8 9 Ā± 0 . 5 5 0.060.22