Research Article

The Effects of QuikClot Combat Gauze, Fluid Resuscitation, and Movement on Hemorrhage Control in a Porcine Model

Table 1

One minute and five minute amount of hemorrhage.

Group1-minute bleed 5-minute bleed
Post hoc results

QuikClot Combat GauzeRange = 149 to 1004 mL Range = 0 to 514 mL One-minute bleed = 0.83
(mean = 654, SD ± 283 mL)(mean = 50, SD ± 154 mL)
Control Range = 100 to 992 mL Range = 0 to 1002 mL Five-minute bleed = 0.018*
(mean = 582, SD ± 259 mL)(mean = 351, SD ± 354 mL)

*Significant < 0.05.