Abstract

Assessment of concrete structures and prediction of their health and life could be possible by online monitoring of the stress/strain level and is an intelligent tool to prevent accidents. Measuring strain pattern on structures is vital to evaluate the health of forced members. The present paper describes the methodology, instrumentation line up, and coding for LabVIEW software for continuous online strain data acquisition of structures for nuclear structures. The performance of strain gauges on concrete and steel containment structures of nuclear reactor and to assess the integrity and health of the containment structure is emphases in this research paper.

1. Introduction

Forced structures, commonly manifested as steel frame structures, reinforcement rods, concrete containments, reinforced concrete beams, prestressed tendons in cement grout, and so forth are subjected to strain due to several loading patterns [1]. Strain is an important criterion which directly governs the service life of structures, and a careful measurement and monitoring of strain induced in forced structures can be used to predict the failure and service life of them. Structures are subjected to a variety of loading patterns which induces different stress patterns on structures according to the type of service conditions that they are subjected to. Temperature variations occur on structures resulting from exposure to sunlight or operational surroundings and nonuniform dissipation of the absorbed heat [2, 3] induces stress. High level of temperature variations may ultimately lead to failure [4]. Naturally, the effect of temperature on the design of containment structures is of major concern particularly in terms of compressive strength, thermal expansion, and long-term deformation under load (creep) [5].

Measurement of stress/strain levels on structures by continuous or online monitoring helps to predict life span of structures and to prevent accidents due to excess loading [6, 7]. Concrete structures are highly sensitive to dynamic loads and exhibit weak resistance to tensile load [8]. Direct measurement of strain under trivial conditions such as earthquake, impact loading, and vibration is not possible. Strain gauges are commonly used as sensors to assess deformation and deflection of structures [8, 9]. Strain gauges are low noise output devices, which need well-insulated low resistance leads. Installation of strain gauges and strain measurement on structures is an art which requires special expertise. While considering the ease of installation and good sensitivity, foil-type strain gauges are normally employed. Considerable amount of work has been carried out on various aspects of strain measurements on structures; however, measurement of strain under different special environments is not well reported. This communication comprehensively presents the methodology, instrumentation, and analysis of stress levels on forced members employing laboratory testing and being extended to onsite evaluation of stress level on steel and concrete containments of nuclear reactors through the online monitoring and the assessment of their health.

The existing literature says that, however, the use of piezoelectric material lead zirconate titanate (PZT) as sensors placed in nonaccessible reinforced concrete members for the detection of damages, the assessment of their severity level, and even more the online monitoring of the possible damage evolution with time [10]. In another paper, studied by the same author, the potential of the detection of flexural damage state in the lower part of the midspan area of a simply supported reinforced concrete beam using piezoelectric sensors is analytically investigated [11]. The problem of comparing two different smart damping techniques using the numerical modelling of the electromechanical impedance for plate structures with piezoelectric sensors is addressed [12].

2. Experimental

2.1. Selection and Installation of Strain Gauges

Most of the structures are monitored by conventional strain gauges and the gauges are based on the working of the electrical signal [9]. The universally acceptable method is the Wheatstone bridge circuit method [1318]. Installation of strain gauges on the concrete/steel surface has been carried out in accordance with ASTM standard (E1237-93; 2003—standard guide for installing bonded resistance strain gauges) and the manufacturer’s recommendations [19].

The installation of strain gauge involves selection of locations, preparation of surface, and fixing. The selected surface is scratched and degreased and the strain gauges are fixed with suitable adhesive. Surface preparation ensures healthy bonding of strain gauge. Specific adhesives are used for steel and concrete surfaces. Adhesive plays a vital role in transferring energy from the surface to the strain gauge and assuring firm bonding between the two surfaces. It also fills up the pores in concrete and provides better linkage. Cyano-Acrylate (TML, Japan), which has quick setting property, is a suitable adhesive for steel surfaces, while epoxy-based adhesives (P-2 TML) can be employed for concrete structures. Because, at the time of concrete cracking, the possibility of the detachment of strain gauges from the structure is high. The epoxy-based-two component adhesives ensure good adhesion of strain gauges to the concrete surface [20, 21].

Foil-type strain gauges of model no. KFG-10-120-C1-11 (KYOWA, Japan) of resistance 120 ohms with gauge factor (G.F) 2.09 were used for laboratory measurement of concrete members.

Strain gauges model no. FLA-6-11 and PL-120-11 (TML, Japan) of resistance 120 ohms with gauge factor 2.13 were used for steel surface at containment dome and concrete containment surface, respectively.

2.2. Data Acquisition

Data acquisition (DAQ) is a continuous recording of signals from the installed strain gauges for the structural health monitoring and evaluation. It may be periodic or an online measurement. DAQ system comprises three major sections, such as hardware for data measurement and logging, and communication linkage to the computer (PC), embedded software interface. Data measurement unit may be as simple as a multimeter or a sophisticated instrumentation for continuous measurement. Special instrumentations are preferred for online measurements. The communication linkage employs either traditional analog signal interface sensors with distributed process control system or the relatively simple and modern digital networks called field-buses and ethernet chord [22]. Modern DAQ system uses ethernet interface, that is, internet protocol (TCP/IP) protocol communication or a serial communication (RS-232) with the computer.

2.3. Strain Measurement

National instruments (NI) DAQ card with NI LabVIEW software interface was used for measuring stain values of concrete members in laboratory experiments. For onsite, Hewlett Packard 34970A DAQ card, coupled with field point modules (NI make), was employed for the measurement of strain on steel/concrete surfaces. The scheme of strain measurement instrumentation is presented in Figure 1.

The specifications of the instrumentations are as follows:(1)Name and make: FieldPoint modules, national instruments.Card name: FieldPoint strain gauge module (NI FP-SG-140) as follows:(i)15, 60, or 240 Hz filters, software configurable per channel;(ii)16-bit resolution, 8 channels;(iii)2.5, 5, or 10 V excitation levels, software configurable per channel.Controller: FieldPoint ethernet controller (NI FP-2000) as follows:(i)Stand-alone embedded real-time controller or Ethernet interface for PC-based distributed I/O;(ii)16-MB onboard DRAM memory, 32 MB ROM;(iii)Advanced control, data logging, and signal processing capabilities.(2)Name and make: 34970A data acquisition/switch unit, Hewlett Packard.Card Name: Agilent 34902A, 16 Channel, Reed Multiplexer module.  22-bit resolution, 8 channels (4 wires) or 16 channels (2 wires).

Onsite measurements use HP-Benchlink software version 1.1, while the laboratory measurement coding was developed using NI LabVIEW software version 7.0.

The algorithm developed for the software coding for strain measurement is explained below.(1) Development of server VI by Lab-VIEW real time for the strain measurement.(a)Coding for retrieval of data from DAQ card through FieldPoint module was done.(b)Coding was done to communicate the measured data with time stamp using TCP/IP port to the PC.(2) Coding for Client VI by the LabVIEW software.(a)Coding for data retrieval from the TCP/IP port was done.(b)Coding was done for the conversion of the measured resistance values to the microstrain.(c)Provide the user interface and display in the Client VI such as graphs, strain data and time stamp.(3) Strain data managing coding by LabVIEW data logging and supervisory control (DSC) coding are as follows.(a)Coding was done for continuous data storage in citadel data base and spread-sheet file.(b)Data storing to provide the tag information for the specific strain gauge was done.(c)Historical trend view program was simply modified for the specific strain gauge. The main VI of historical view was inbuilt and supplied by the NI LabVIEW. Configuration of hardware was carried out after coding followed by running the VI program. The following steps were involved to run the VI program.(1)Wiring:strain gauge leads were connected to DAQ card.(2)Configuration of DAQ in PC:(a)power on and connect the Field point to the PC by ethernet cable;(b)by using LabVIEW-measurement automation explorer (MAX) theFieldPoint modules targets were configured for communication;(c)by MAX corresponding DAQ card channel was configured such as bridge circuit and excitation voltage.(3)Running the program:(a)download and run the Server VI to the FieldPoint modules;(b)run the Server VI in personal computer.

By running both the Server VI and Client VI, the measurements were recorded online by the NI-DAQ card (FieldPoint modules) and software (LabVIEW) from the strain gauge.

2.4. Onsite Strain Measurement

Nuclear reactor containment is one of the critical structures in nuclear power plants. These containment structures are subjected to internal leak proof tests before its commissioning. They are subjected to high pressure. The strain measurement of concrete and steel containment structures during these tests is very vital to ensure the integrity of the structure and assess their health for the safety operation of nuclear reactor. Methodology, field worthiness, installation and online measurement of strain induced on concrete structures employing foil type strain gauges have been ascertained at laboratory testing. The use of these strain gauges for onsite measurement of strain of concrete and steel containment structures has been envisaged to assess their health. A set of strain gauges (9 nos.) was installed on identified locations and labelled from SE-01 to SE-09. Three gauges, namely, SE-01 to 03 were employed to measure the strain on concrete containment, and the gauges SE-04 to 09 were fixed on steel containment. The gauges were linked to the field point modules and HP data logger. The schematic layout of the strain gauges and their locations at the containment is shown in the Figures 2 and 3. The strain gauge readings were continuously recorded for 9 days and 10 minutes interval.

Four wire resistance techniques were adopted for the measurement of resistance values of strain gauges. Microstrain induced in the structure can be calculated from the following relationship: where is the micro strain, is the change in resistance in ohms, is the initial resistance in ohms, is the observed resistance in ohms, and Gauge factor is the a constant given by the manufacturer.

2.5. Measurements Schedule

Integrated leakage rate test (ILRT)/proof test was conducted for 7 days, continuous monitoring of measurement was recorded at an interval of 10 minutes. The chronological events of ILRT proof test are shown in the Table 1.

3. Results and Discussion

3.1. ILRT Results
3.1.1. Concrete SMER’s at Stressing Gallery

The proof test conducted for nuclear reactor containment is shown in Figure 4. The SMER’s for concrete surface installed in stressing gallery is as follows: SE-01, SE-02, and SE-08. From the figure it is observed that the maximum micro strain value reached during the pressure at 1.73 kg/cm2 was 8 and gradually decreased to a value of −7.0 for SE-01 at 0 pressure level. Similarly the maximum micro strain values for SE-02 and SE-08 were 17.7 and −13.0, respectively, for the pressure at 1.73 kg/cm2, and minimum microstrain values were −10.1 and 15.6 at the pressure 0.0 kg/cm2. The reading was also recorded after 24 hr. From the figure it is evident that SMER’s response was good. The performances of the various sensors were satisfactory, and the subsequent data analysis showed that the containment structure response was elastic during the loading and unloading stages, and the test results were found to be in reasonable agreement.

3.1.2. Concrete SMER at Ring Beam

Figure 5 shows the SMER for concrete surface installed in stressing gallery (SE-25). From the figure, it is observed that the maximum microstrain values reached during the pressure at 1.73 kg/cm2 were −28.1 and gradually decreased to 24.1. The values obtained for the SMER installed in concrete surface depict clearly the dip below the axis and gradually increase to the positive side. The response of the SMER was found as that of the previous SMER. As the pressure test for the containment was in progress, the micro stain values also increased during pressuring and gradually decreased in depressurization. The containment structure response was elastic during the pressuring and depressurization stages, and the test results were found to be in sensible agreement.

3.1.3. Steel SMER’s at Dome

Figure 6 shows the SMER’s for the steel surface installed in the dome and labelled as SE-55, SE-56 and SE-57. From the figure, it is evident that the maximum micro strain values reached during the pressure at 1.73 kg/cm2 were 102.7, 38.6, and 20.8. Minimum microstrain values were −8.1, −4.5, and −5.2 that were observed after stabilization of 0 Kg/cm2 pressure. The stabilization reading after 24 hrs is shown in the Table 3. There is no much change in the microstrain values. From the figure, it is evident that all the steel SMER’s response was found to be intact with the steel surface throughout the proof test. Hence, from the test it can be concluded that the response of the steel SMER’s was found to be satisfactory.

3.1.4. Steel SMER’s at Dome

Figure 7 shows the SMER for the steel surface installed in the dome (SG) and labelled as SE-58, SE-59, and SE-60. From the figure it is evident that the maximum microstrain values reach were during the pressure at 1.73 kg/cm2 was 34.8, 97.5, and 33.9. Minimum micro strain values were −7.2, −1.2, and −4.5 that were observed after stabilization of pressure 0.0 Kg/cm2. Stabilization reading after 24 hrs shows that there is no much change in the values of micro strain, is similar to that of pressure 0 kg/cm2, and can be inferred as in Table 3. It is evident that all the steel SMER response was found to be intact with the steel surface throughout the proof test. Hence, from the test it can be concluded that the response of the steel SMER’s was found to be satisfactory.

Table 2 shows the pressure up reading, and Table 3 shows the pressure down reading. From Table 2 the strain measurements for steel SMER are for nuclear reactor containment for the pressure test from 0.0 to 1.73 kg/cm2. The micro stain values of SE-55 and SE-59 at different pressure was found to be in increasing trend throughout the pressure test. This indicates that the response of the SMER was satisfactory. In the case of SE-56 to SE-58 and SE-60 the micro stain values were increasing. During pressuring it was witnessed in some SMERs decreased trend was followed. The response of the SMER sensibility was good. As the pressure increases the dome expanded. Gradually pressure increases the concrete side wall, and the dome expands. After sometimes there is a limit for steel and steel is reduced, and the side wall expands for further pressure.

Consequently the strain measurements for concrete SMER’s for nuclear reactor contaminant during pressure test were from 0.0 to 1.73 kg/cm2. All concrete SMER’s the micro strain values at different pressure was found to be increasing trend throughout the pressure loading; this indicates that the response of the SMER’s was satisfactory, and a linear trend was observed.

Table 3 depicts the strain measurements for steel SMER’s at pressure 1.73 to 0.0 kg/cm2; the micro stain values at depressurization were found to be in decreasing trend throughout the pressure down. Similarly strain measurements for concrete SMERs the micro strain values at pressure down were found to be a decreasing trend throughout the pressure test. This indicates that the response of the SMER’s was satisfactory, and a linear trend was observed. In general the structural system has been sustained within its elastic limits. Temperature correction was carried for the three cycles, and average temperature correction was arrived.

4. Conclusions

The following broad conclusions were observed during ILRT for SMER’s.(1)The larger strain values of steel structures can be attributed to the temperature effect due to the open exposure to the sun light as these structures form the roof top of the containment and the ductility of steel which can take more strain.(2)The data readings were collected for every 10 minutes for the entire test period.(3)The performances of the various sensors were satisfactory, and the subsequent data analysis showed that the containment structure response was elastic during the loading and unloading stages and the test results were found to be in reasonable agreement.(4)The Strain Measurements for Steel SMER’s, pressure 0.0 to 1.73 kg/cm2. SE-55 and SE-59 the steel SMER’s the micro strain values at different pressure was found to be increasing trend throughout the pressure loading, this indicates that the response of the SMER’s was satisfactory, a linear trend was observed.(5)In the case of SE-56 to 58 and SE-60 the micro stain values were increasing during pressuring, and there was decreased trend in some cases was noticed. The response of the SMER’s sensibility was good.

In the case of pressure down from 1.73 to 0.0 Kg/cm2 strain values for concrete and steel SMER’s were found to be decreasing trend throughout the depressurization; this indicates that the response of the SMER’s was satisfactory, and a linear trend was observed.

In general the structural system has been sustained within its elastic limits. The present paper describes the methodology, instrumentation line up, and software for continuous online strain data acquisition of structures. Measuring strain pattern on structures is vital to evaluate the health of forced members. They can be used for strain measurement even at elevated temperatures. The performance of strain gauges on concrete and steel containment structures of nuclear reactor is to assess the integrity and health of the containment structure.

Conflict of Interests

The authors declare that they have no conflict of interests.

Acknowledgment

The authors thank the Director of CECRI, Karaikudi, India, for his support to carry out this study.