Research Article
An Approximate Analytical Method for the Evaluation of the Concentrations and Current for Hybrid Enzyme Biosensor
Table 3
Comparison between the analytical normalized reducing agent concentration
(
14) and numerical simulation for various values of
and
.
| | | | | Our work (14) | Numerical | % Error | Our work (14) | Numerical | % Error | Our work (14) | Numerical | % Error |
| 0.0 | 0.1000 | 0.1000 | 0.00 | 0.5000 | 0.5000 | 0.00 | 1.0000 | 1.0000 | 0.00 | 0.2 | 0.0934 | 0.0934 | 0.00 | 0.4671 | 0.4671 | 0.00 | 0.9343 | 0.9341 | 0.02 | 0.4 | 0.0884 | 0.0884 | 0.00 | 0.4421 | 0.4420 | 0.02 | 0.8843 | 0.8840 | 0.03 | 0.6 | 0.0849 | 0.0849 | 0.00 | 0.4246 | 0.4244 | 0.05 | 0.8491 | 0.8488 | 0.03 | 0.8 | 0.0828 | 0.0828 | 0.00 | 0.4141 | 0.4139 | 0.05 | 0.8283 | 0.8279 | 0.05 | 1.0 | 0.0821 | 0.0821 | 0.00 | 0.4107 | 0.4105 | 0.05 | 0.8214 | 0.8210 | 0.05 |
| ā | Average deviation | 0.00 | Average deviation | 0.03 | Average deviation | 0.03 |
|
|