Research Article

Corrosion Study of Powder-Coated Galvanised Steel

Table 2

Impedance parameters of wash primer and epoxy primer and top coated GI in 3.5% NaCl solution.

Time, hSystem-1System-2
resistance (Ω/cm2)resistance (Ω/cm2)

Initial8.835 × 1061.166 × 106
24 h7.203 × 1041.446 × 105
96 h73671.185 × 105
144 h71661.633 × 104
264 h55041.576 × 104