Research Article
The Development of a Mathematical Model for the Prediction of Corrosion Rate Behaviour for Mild Steel in 0.5 M Sulphuric Acid
Table 2
Result of corrosion rate without and with inhibitor at different temperature and time.
| Inhibitor concentration (% v/v) | Mild steel corrosion rate (mpy) | 30°C | 50°C | 70°C | Time (mins) |
| 0 | 51.71 | 62.41 | 70.43 |
135 | 2 | 23.26 | 28.72 | 35.20 | 4 | 17.06 | 21.84 | 27.16 | 6 | 14.47 | 19.35 | 25.35 | 8 | 11.94 | 17.47 | 21.14 | 10 | 11.02 | 14.09 | 18.61 |
| 0 | 49.81 | 60.23 | 69.11 |
180 | 2 | 16.28 | 23.08 | 28.81 | 4 | 9.93 | 12.69 | 17.23 | 6 | 8.61 | 11.88 | 14.71 | 8 | 6.92 | 10.82 | 13.15 | 10 | 7.18 | 9.98 | 12.74 |
| 0 | 43.63 | 56.41 | 63.60 |
270 | 2 | 10.57 | 14.54 | 17.95 | 4 | 8.29 | 10.72 | 13.35 | 6 | 6.83 | 10.35 | 12.50 | 8 | 6.61 | 8.95 | 10.27 | 10 | 6.73 | 8.79 | 10.23 |
|
|