Research Article

The Study of Cooling Process on Runout Table by Simulation Method

Table 2

Output of surface temperature at ROT.

Case study no.Entrance ROT temperature 
Reference at exit ROT temperature 
Actual surface temperature 
True errorPercent relative error 

11148793754.3138.690.048789407
21148793720.772.30.091172762
31148793458.85334.150.421374527
41148793455.25337.750.42591425
51148793679.96113.040.142547289
61148793455.25337.750.42591425
71148793679.96113.040.142547289
81148793503.6289.40.364943253
91148793441.85351.150.442812106
101148793440.4352.60.444640605
111148793375.32417.680.526708701
121148793378.7414.30.522446406