Research Article
The Study of Cooling Process on Runout Table by Simulation Method
Table 2
Output of surface temperature at ROT.
| Case study no. | Entrance ROT temperature
| Reference at exit ROT temperature
| Actual surface temperature
| True error | Percent relative error
|
| 1 | 1148 | 793 | 754.31 | 38.69 | 0.048789407 | 2 | 1148 | 793 | 720.7 | 72.3 | 0.091172762 | 3 | 1148 | 793 | 458.85 | 334.15 | 0.421374527 | 4 | 1148 | 793 | 455.25 | 337.75 | 0.42591425 | 5 | 1148 | 793 | 679.96 | 113.04 | 0.142547289 | 6 | 1148 | 793 | 455.25 | 337.75 | 0.42591425 | 7 | 1148 | 793 | 679.96 | 113.04 | 0.142547289 | 8 | 1148 | 793 | 503.6 | 289.4 | 0.364943253 | 9 | 1148 | 793 | 441.85 | 351.15 | 0.442812106 | 10 | 1148 | 793 | 440.4 | 352.6 | 0.444640605 | 11 | 1148 | 793 | 375.32 | 417.68 | 0.526708701 | 12 | 1148 | 793 | 378.7 | 414.3 | 0.522446406 |
|
|