Research Article

Randomized, Controlled Comparison of Advanced Hemostatic Pads in Hepatic Surgical Models

Figure 2

Kaplan-Meier plot for interval censored time of hemostasis of Hemopatch and TachoSil, where the time interval during which hemostasis occurred is shaded. Hemopatch, approximated for 2 min, achieved immediate hemostasis in 100% (95% CI: 72.3% to 100%) of applications; while TachoSil, approximated for 3 min, achieved immediate hemostasis in 80% (95% CI: 49.0% to 94.3%) of applications. One TachoSil-treated animal did not achieve hemostasis within the 15-minute observational period.
930803.fig.002a
(a)
930803.fig.002b
(b)