Research Article

The Application of Response Surface Methodology in the Study of Photodegraded Industrial Dairy Effluents by the Photo-Fenton Process: Optimization and Economic Viability

Table 3

Results of physical/chemical analyses in natura and posttreatment dairy effluents.

ParametersResultsData in the literatureReferencesRelease standards* (mg L−1)
In Natura After AOPs and precipitation

AspectTurbidClear
True color (Co Pt)431.927.86Absent
Turbidity (NTU)103312.00Absent
pH6.0–6.48.0–8.505.25–8.0[17, 1921]5–9
OdorPungentAbsent
COD (mg L−1 O2)9000–10000929.0–935.0797–8000[1921]
BOD (mg L−1 O2)2300–2500508.5–515.81292–60000[20]60
BOD/COD0.250.65
DOC (mg L−1)1513–1800336.2–356.12500–5000[5, 20]
Phosphorus (mg L−1)108.73.038.6–227.1[17, 20]
NH3-N (mg L−1)158.00.00270.25–57[19]20
Organic N (mg L−1)179.90.004716.5–1048[19, 20]
aST (mg L−1)56802830.60545–15720
bSTF (mg L−1)986880119
cSTV (mg L−1)48001746.0426–10900[19]
Phenol (mg L−1)>0.005>0.0050.5
Oil and grease (mg L−1)2002.50.0004680[22]50
Chloride (mg L−1)1301.7527.0
Cyanide (mg L−1)AbsentAbsent0.2
Copper (mg L−1)1.397.81.0
Chromium (mg L−1)AbsentAbsent0.1
Cadmium (mg L−1)0.2460.2540.2
Iron (mg L−1)48.480.01315.0
Lead (mg L−1)0.0310.0280.5
Zinc (mg L−1)5.005.005.0
Manganese (mg L−1)3.1202.9401.0
Nickel (mg L−1)0.390.322.0

ST: total solids, bSTV: fixed solids, and cSTV: total volatile solids.
*Standards for effluent release in water bodies (Article 18 CETESB CONAMA 357/05). (—): not specified.