Table 2
Parameters of five-phase induction machine.
Parameter
Symbol
Value
Dimension
Rated power
1,5
kW
Rated speed
2830
rpm
Rated current
1,7
A
Rated slip
2,8
Hz
Rated voltage
230
V
Stator resistance
9,5
Rotor resistance
6,68
Total inertia (test + load machine)
0,01148
Main inductance
1,114
H
Stator leakage inductance
0,0269