Research Article

Two-Dimensional Key Table-Based Group Key Distribution in Advanced Metering Infrastructure

Algorithm 1

Example of selection of group key generation element.
Location of smart meter ( )
Coordinates of = 50, = 40
Group key generation element of on key table
= ( + 10) − (PRNG(·) mod 20)
  = (50 + 10) − (PRNG(·) mod 20)
= ( + 10) − (PRNG(·) mod 20)
  = (40 + 10) − (PRNG(·) mod 20)