Step  3F4 worksheet: misinterpretation of the results.

Step 4: failure risk analysisStep 5: correction/action/result
Rating*Decision tree
Reasons for failure GRPNWith Control mechanismProblems DetectableContinuedCorrectionActionResultRole in charge

Step 3F4aToo tired9820.874NoYesYesControlConfirmed by second examinationConfirmed by two examinersLaboratory director
3F4bToo busy3980.663NoNoYesControlPersonnel access control and provision of a single telephoneReplacement of laboratory and telephone systemGeneral department
3F4cInsufficient light2880.542NoNoStopProvide a second light sourceInstallation of new lightsBrighter lightsGeneral department
3F4dMisunderstanding of the machine report8640.836NoYesYesNeed to deal withPurchase new equipmentEquipment installed on a given date (YY/MM/DD)Procurement department