Table of Contents Author Guidelines Submit a Manuscript
Journal of Automated Methods and Management in Chemistry
Volume 2007, Article ID 39761, 4 pages
http://dx.doi.org/10.1155/2007/39761
Research Article

Comparison Study of Different BOD Tests in the Determination of BOD7 Evaluated in a Model Domestic Sewage

1Department of Chemistry, Faculty of Science, University of Oulu, P.O. Box 3000, Oulu 90014, Finland
2Water Resources and Environmental Engineering Laboratory, Department of Process and Environmental Engineering, Faculty of Technology, University of Oulu, P.O. Box 4300, Oulu 90014, Finland
3Oulu Waterworks, Kasarmintie 29, Box 35, Oulu 90015, Finland

Received 9 October 2006; Accepted 26 April 2007

Copyright © 2007 Katri Roppola et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. J. Liu, L. Björnsson, and B. Mattiasson, “Immobilised activated sludge based biosensor for biochemical oxygen demand measurement,” Biosensors and Bioelectronics, vol. 14, no. 12, pp. 883–893, 2000. View at Publisher · View at Google Scholar
  2. J. Liu and B. Mattiasson, “Microbial BOD sensors for wastewater analysis,” Water Research, vol. 36, no. 15, pp. 3786–3802, 2002. View at Publisher · View at Google Scholar
  3. K. Roppola, T. Kuokkanen, H. Nurmesniemi, J. Rämö, R. Pöykiö, and H. Prokkola, “Comparison study of manometric respirometric test and common chemical methods in the determination of BOD7 in a pulp and paper mill's wastewaters,” Journal of Automated Methods and Management in Chemistry, vol. 2006, Article ID 90384, 5 pages, 2006. View at Publisher · View at Google Scholar
  4. T. Kuokkanen, P. Vähäoja, I. Välimäki, and R. Lauhanen, “Suitability of the respirometric BOD OxiTop method for determining the biodegradability of oils in ground water using forestry hydraulic oils as model compounds,” International Journal of Environmental Analytical Chemistry, vol. 84, no. 9, pp. 677–689, 2004. View at Publisher · View at Google Scholar
  5. P. Vähäoja, T. Kuokkanen, I. Välimäki, S. Vuoti, and P. Perämäki, “Biodegradabilities of some chain oils in groundwater as determined by the respirometric BOD OxiTop method,” Analytical and Bioanalytical Chemistry, vol. 381, no. 2, pp. 445–450, 2005. View at Publisher · View at Google Scholar
  6. P. Vähäoja, P. Piltonen, A. Hyvönen, J. Niinimäki, J. Jalonen, and T. Kuokkanen, “Biodegradability studies of certain wood preservatives in groundwater as determined by the respirometric BOD OxiTop method,” Water, Air, & Soil Pollution, vol. 165, no. 1–4, pp. 313–324, 2005. View at Publisher · View at Google Scholar
  7. P. Vähäoja, K. Roppola, I. Välimäki, and T. Kuokkanen, “Studies of biodegradability of certain oils in forest soil as determined by the respirometric BOD OxiTop method,” International Journal of Environmental Analytical Chemistry, vol. 85, no. 14, pp. 1065–1073, 2005. View at Publisher · View at Google Scholar
  8. WTW Weilheim, “OxiTop instruction manual,” Germany.
  9. SFS-EN 1899-1, Water quality. Determination of biochemical oxygen demand after n days (BODn)—Part 1: Dilution and seeding method with allylthiourea addition.
  10. SFS-EN 25813, Water quality. Determination of dissolved oxygen. Iodometric method.
  11. SFS-EN 25814, Water quality. Determination of dissolved oxygen. Electrochemical probe method.
  12. Endress and Hauser, “StamoSens CSM 750 / CSS 70, users manual”.