Research Article

UHPLC-PDA Assay for Simultaneous Determination of Vitamin D3 and Menaquinone-7 in Pharmaceutical Solid Dosage Formulation

Table 3

Statistical evaluation of regression data of vitamin D3 and MK-7 by HPLC and UHPLC.

ParametersAnalyte/technique
HPLCUHPLC
Vitamin D3MK-7Vitamin D3MK-7

Linearity range (μg mL−1)5–1005–1005–1005–100
Slope19986061363630.58540.5854
Intercept572572470561.4134.52104.52
Standard error of slope9290268083.6 × 10−24.43 × 10−2
Standard error of intercept469133343771.1811.901
Coefficient of determination ()0.99840.99810.99840.9981
Limit of detection (μg mL−1)0.240.270.160.18
Limit of quantification (μg mL−1)0.720.810.480.54